Frymaster 1814E operation manual Power Requirements, Three 3 Phase Requirements

Models: 1814E

1 36
Download 36 pages 49.11 Kb
Page 11
Image 11

2.2Power Requirements

Three (3) Phase Requirements

 

MODEL

VOLTAGE

WIRE

 

SERVICE

 

 

 

 

 

 

 

 

1814E 14kW

208

3

 

1814E 14kW

240

3

 

1814E 14kW

480

3

 

1814E 14kW

220/380

4

 

1814E 14kW

240/415

4

 

1814E 14kW

230/400

4

 

1814E 17kW

208

3

 

1814E 17kW

240

3

 

1814E 17kW

480

3

 

1814E 17kW

220/380

4

 

1814E 17kW

240/415

4

 

1814E 17kW

230/400

4

 

1814E 22kW

208

3

 

1814E 22kW

240

3

 

1814E 22kW

480

3

 

1814E 22kW

220/380

4

 

1814E 22kW

240/415

4

 

1814E 22kW

230/400

4

MINIMUM WIRE

AMPS

 

SIZE

 

(per leg)

AWG

 

(mm)

 

 

6

 

(4.11)

39

6

 

(4.11)

34

8

 

(2.59)

17

6

 

(4.11)

21

6

 

(4.11)

20

6

 

(4.11)

21

6

 

(4.11)

48

6

 

(4.11)

41

6

 

(4.11)

21

6

 

(4.11)

26

6

 

(4.11)

24

6

 

(4.11)

25

4

 

(5.19)

61

4

 

(5.19)

53

6

 

(4.11)

27

6

 

(4.11)

34

6

 

(4.11)

31

6

 

(4.11)

32

Single Phase Requirements

MODEL

VOLTAGE

WIRE

SERVICE

 

 

 

 

 

1814E 14kW

208

2

1814E 14kW

240

2

1814E 14kW

480

2

MINIMUM WIRE

AMPS

 

SIZE

 

(per leg)

AWG

 

 

(mm)

 

 

 

3

 

 

(5.83)

68

4

 

 

(5.19)

59

8

 

 

(3.26)

30

NOTICE

If this appliance is permanently connected to fixed wiring, it must be connected by means of copper wires having a temperature rating of not less than 167°F (75°C).

DANGER

This appliance must be connected to a power supply having the same voltage and phase as specified on the rating plate located on the inside of the appliance door.

DANGER

All wiring connections for this appliance must be made in accordance with the wiring diagram(s) furnished with the appliance. Refer to the wiring diagram(s) affixed to the inside of the appliance door when installing or servicing this equipment.

2.3Positioning the Fryer

DANGER

No structural material on the fryer should be altered or removed to accommodate placement of the fryer under a hood. Questions? Call the Frymaster Service Hotline at 1-800-551-8633.