Frymaster 1814E operation manual Filtration Problems, Error Messages

Models: 1814E

1 36
Download 36 pages 49.11 Kb
Page 33
Image 33

6.2.2 Filtration Problems

Problem

Probable Causes

 

A. Power cord is not plugged in or

 

circuit breaker is tripped.

 

 

 

B. Pump motor has overheated

 

causing the thermal overload

Filter pump won't

switch to trip.

 

start.

 

 

 

 

C. Blockage in filter pump.

 

Test: Close the drain valve and

 

pull the filter pan out from the

 

fryer. Activate the pump. If the

 

pump motor hums for a short time

 

then stops, the probable cause is

 

blockage of the pump itself.

Filter pump runs

Blockage in filter pan suction tube.

Test: Close the drain valve and pull

but oil does not

return to frypot and the filter pan out from the fryer.

there is no bubbling Activate the pump. If bubbling oil

oil. occurs, there is a blockage in the

 

filter pan suction tube.

Filter pump runs,

A. Improperly installed filter pan

but oil return is very

components.

slow and bubbling

 

oil occurs.

 

B.Attempting to filter with oil that is not hot enough.

6.2.3Error Messages

See chapter 2 in the controller manual.

Corrective Action

A. Verify that the power cord is fully plugged in. If so, verify that circuit breaker is not tripped.

B. If the motor is too hot to touch for more than a few seconds, the thermal overload switch has probably tripped. Allow the motor to cool at least 45 minutes then press the Pump Reset Switch.

C. Pump blockages are usually caused by sediment buildup in the pump due to improperly sized or installed filter paper and failure to use the crumb screen. Call a FAS.

The blockage may be caused by sediment buildup or, if solid shortening is used, solidified shortening in the tube. Use a thin, flexible wire to remove the blockage. If the blockage cannot be removed, call a FAS.

A. If using filter paper or pad configuration, verify that filter screen is in bottom of pan with paper or pad on top of screen.

Verify that O-rings are present and in good condition on filter pan connection fitting.

If using Magnasol filter assembly, verify that O-ring is present and in good condition on filter screen fitting.

B. See filter section on page 4-8.

6-3

Page 33
Image 33
Frymaster 1814E operation manual Filtration Problems, Error Messages