Frymaster 1814E operation manual Problem Probable Causes Corrective Action

Models: 1814E

1 36
Download 36 pages 49.11 Kb
Page 32
Image 32

6.2Troubleshooting

6.2.1 Controller and Heating Problems

Problem

Probable Causes

Corrective Action

 

A. Power cord is not plugged in or

A. Plug power cord in and verify

 

that circuit breaker is not

 

circuit breaker is tripped.

Controller won't

tripped.

 

activate.

B. Controller or power supply

B. Call a FAS.

 

component or interface board has

 

 

failed.

 

 

 

A. A drain safety switch prevents

 

 

the heating element from being

 

A. Drain valve is open.

energized if the drain valve is

Fryer does not heat.

 

not fully closed. Verify that the

 

 

drain valve is fully closed.

 

B. One or more other components

B. Call a FAS.

 

have failed.

 

 

 

This is normal. The default

 

 

operational mode is for the

 

 

elements to cycle on and off until

 

 

the temperature in the frypot

 

 

reaches 180ºF (82ºC). MLT-

Fryer repeatedly

 

CYCL will appear in the display

 

when in the melt-cycle mode. The

cycles on and off

Fryer is in melt-cycle mode.

purpose of the melt-cycle is to

when first started.

 

 

allow controlled melting of solid

 

 

 

 

shortening to prevent scorching

 

 

and flash fires or damage to the

 

 

element. To bypass melt cycle

 

 

press and hold the exit cool button.

 

 

When prompted, press yes.

 

 

This fryer is equipped with a drain

Fryer does not heat

 

safety switch that prevents the

Drain valve is open.

heating element from being

after filtering.

energized if the drain valve is not

 

 

 

fully closed. Verify that the drain

 

 

valve is fully closed.

Fryer heats until

Temperature probe or controller has

Turn fryer off and call a FAS.

high limit trips with

failed.

 

heat indicator ON.

 

 

 

Fryer heats until

 

 

high limit trips

Contactor or controller has failed.

Call a FAS.

without heat

 

 

indicator ON.

 

 

Fryer stops heating

The high limit thermostat or

Call a FAS.

with heat indicator

 

contactor has failed.

 

ON.

 

 

 

6-2

Page 32
Image 32
Frymaster 1814E operation manual Problem Probable Causes Corrective Action, Troubleshooting Controller and Heating Problems