Non-CE Standard

Burner Manifold Gas Pressures

Gas

Pressure

Natural

3.5" W.C.

0.73 kPa

 

Propane

8.25" W.C.

2.05 kPa

 

 

 

 

 

CE Standard

Burner Manifold Gas Pressures

Gas

Pressure

(mbar)

 

Natural Gas Lacq

7,5

(G20) under 20 mbar

 

Natural Gas Gronique *

10

(G25) under 25 mbar

 

Natural Gas Gronique

10

(G20) under 20 mbar

 

Propane

20,6

(G31) under 37 or 50 mbar

 

* Belgian G25 = 7,0 mbar

 

 

 

 

 

4.If the measured gas pressure does not match the appropriate pressure in the tables above, remove the cap from the gas valve regulator and adjust to the correct pressure.

Robertshaw Valve

Honeywell Valve

Honeywell Valve

(Non-CE Units)

(Non-CE Units)

(CE Units)

Regulator Adjustment Screw Cap

5.Place the fryer power switch and the gas valve in the OFF position. Remove the fitting from the pressure tap hole and reinstall the plug. Place the gas valve in the ON position, and check for and eliminate any gas leaks. Place the gas valve in the OFF position.

1.4Adjusting the Pilot Flame

1.On non-CE valves, remove the cap covering the pilot adjustment screw. On all valves, turn the pilot adjustment screw counterclockwise to increase the length of the flame or clockwise to de- crease the length of the flame. Adjust the flame to a length of 1 to 1½ inches (25 to 38mm).

To access the pilot adjustment screw on

Pilot Adjustment Screw

Non-CE valves, this cap must be removed.

 

Robertshaw Valve

Honeywell Valve

Honeywell Valve

(Non-CE Units)

(Non-CE Units)

(CE Units)

2.On Non-CE valves, reinstall the pilot adjustment screw cap.

1-5

Page 11