Burner Manifold Gas Pressures
Gas | Pressure | |
Natural | 3.5" W.C. | |
0.73 kPa | ||
| ||
Propane | 8.25" W.C. | |
2.05 kPa | ||
| ||
|
| |
|
|
CE Standard
Burner Manifold Gas Pressures
Gas | Pressure | |
(mbar) | ||
| ||
Natural Gas Lacq | 7,5 | |
(G20) under 20 mbar | ||
| ||
Natural Gas Gronique * | 10 | |
(G25) under 25 mbar | ||
| ||
Natural Gas Gronique | 10 | |
(G20) under 20 mbar | ||
| ||
Propane | 20,6 | |
(G31) under 37 or 50 mbar | ||
| ||
* Belgian G25 = 7,0 mbar |
| |
|
| |
|
|
4.If the measured gas pressure does not match the appropriate pressure in the tables above, remove the cap from the gas valve regulator and adjust to the correct pressure.
Robertshaw Valve | Honeywell Valve | Honeywell Valve |
(CE Units) |
Regulator Adjustment Screw Cap
5.Place the fryer power switch and the gas valve in the OFF position. Remove the fitting from the pressure tap hole and reinstall the plug. Place the gas valve in the ON position, and check for and eliminate any gas leaks. Place the gas valve in the OFF position.
1.4Adjusting the Pilot Flame
1.On
To access the pilot adjustment screw on | Pilot Adjustment Screw |
|
Robertshaw Valve | Honeywell Valve | Honeywell Valve |
(CE Units) |
2.On