1.10.1 Troubleshooting the 24VAC Circuit in Units without Interface Boards

Verify that the ON/OFF switch is in the ON positon.

Is 24VAC

 

 

 

Is 24VAC

 

 

 

Probable cause

present at the gas

 

No

 

present at the ON/OFF

 

No

 

is a failed 24-volt

 

 

 

 

valve?

 

 

 

switch?

 

 

 

transformer.

 

 

 

 

 

Yes

Yes

Is the continuity

 

 

 

Probable cause

of the ON/OFF switch OK

 

 

 

 

No

 

is a failed ON/OFF

(zero resistance in the ON

 

 

 

 

 

switch.

 

 

 

position)?

 

 

 

 

 

 

 

Yes

Verify that the temperature

of the cooking oil/

shortening is at least 15

degrees below the thermostat setting.

Is continuity of

 

 

 

Probable cause is a

the thermostat OK (zero

 

No

 

 

 

failed thermostat.

resistance)?

 

 

 

 

 

 

 

 

 

 

Problem is with the gas valve.

Refer to Troubleshooting the Gas Yes

Valve on Page 1-33.

1-29

Page 35
Image 35
Frymaster 45 Series manual Verify that the ON/OFF switch is in the on positon