3.8 Gas Conversion Kits (cont.)

SR52G Propane to Natural Gas Components

QTY

REF

DESCRIPTION

 

 

 

1

TJ024

Pilot orifice

 

 

 

5

14-0067-1

Burner orifice, #39

(diameter: 2.53 mm)

 

 

 

 

 

1

Label

Appareil réglé pour: G20/20

Fryer equipped for: G25/25

 

 

 

 

 

3.9 Electrical Connections

No outside electrical power source is required for Super Runner gas fryers unless outfitted with certain optional equipment (i.e. basket lifts). Refer to the rating plate and wiring diagram located inside the front door. The diagram can also be found in Section 8.4. All electrically operated appliances must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code (ANSI/NFPA 70), the Canadian Electrical Code (CSA C22.2), or the appropriate CE community standards. Do not cut or remove the ground prong from the power cord plug. Respect the phase – neutral polarity.