5. FILTER TROUBLESHOOTING:

5. FILTER TROUBLESHOOTING:

The problems and possible solutions covered are those most commonly encountered.

To troubleshoot, perform the test set-up at the beginning of each condition. Start at the top of the diagram. Arrows direct the troubleshooter through the sequence. Follow each step in sequence as shown in the troubleshooting diagrams.

Troubleshooting Diagram Index

Section

Problem

Page

5.1

Super Cascade filter pump fails to pump oil?

6

5.2

Rate of oil return slowing?

7

5.3

Blockage between filter pan and oil return valve?

8

WARNINGS!

INSPECTION, TESTING, AND REPAIR OF GAS OR ELECTRICAL EQUIPMENT SHOULD BE PERFORMED BY QUALIFIED PERSONNEL.

USE EXTREME CARE DURING ELECTRICAL CIRCUIT TESTS. LIVE CIRCUIT WILL BE EXPOSED.

5.1 SUPER CASCADE FILTER PUMP FAILS TO PUMP OIL?

Filter pump fails to pump oil.

Reset filter circuit

breaker and wall circuit breaker (if necessary).

Turn pump motor ON by turning the oil return handle.

Does oil flow?

No

Is the pump

No

 

motor running?

 

 

 

 

 

 

Yes

 

Yes

 

 

 

 

 

 

 

 

 

 

Conduct

Contact your

 

normal filter

Frymaster

 

operations.

Servicer.

 

There may be

blockages in the

oil lines.

Go to page 7 and follow procedures for Rate of Oil Return Slowing.