Frymaster Combinations, 824E, 2424E operation manual Danger

Models: 2424E 824E Combinations

1 30
Download 30 pages 14.58 Kb
Page 12
Image 12
Manual background

fryers without the built-in boil out option, the power switch is on the front panel. For those with the option, the switches are located inside the door.

When this switch is in the POWER position, this indicator will be lit whenever the heating elements are engergized.

If this light does not remain lit when switch is released, the drain valve is open.

NOTE: The Fryer Reset switch and Boil Out switch are not present in all configurations.

3.The light in the POWER switch should illuminate, indicating that the elements have been energized (see illustration above). It will remain lit until the fryer reaches the temperature set on the thermostat or controller.

4.When the water in the frypot begins to boil, reset the thermostat to 200°F (95°C) or less to verify that the elements and thermostat or controller are functioning correctly. The elements should turn off and the water should stop boiling.

If the elements DO NOT turn off, press the POWER switch to the OFF position. If you are not a Frymaster/Dean certified technician, call your local FASC for service. DO NOT attempt to operate the fryer until the problem has been corrected!

If you are a certified technician, refer to the troubleshooting guides in Chapter 5 of this manual.

5.FOR UNITS EQUIPPED WITH THE OPTIONAL BOILOUT SWITCH: Press the switch to the BOIL OUT position (see illustration on Page 2-4). This feature will maintain the frypot temperature at 195°F (90°C) until the switch is placed in the OFF position. Simmer the solution for approximately 1 hour. Do not allow the water level to drop below the bottom OIL LEVEL line in the frypot during the boilout operation.

FOR UNITS WITHOUT THE OPTIONAL BOILOUT SWITCH: Reset the operating thermostat to 195° (90°C). Simmer the solution for approximately 1 hour. Do not allow the water level to drop below the bottom OIL LEVEL line in the frypot during the boilout operation.

Manual background DANGER

Do not leave the fryer unattended during the boilout process. The boilout solution may foam and overflow. Press the POWER switch to the "OFF" position to control this condition.