FGP55 Rethermalizer Sequence of Operation
1.Ensure the unit is properly installed. Check the following:
a.Rethermalizer is level under the vent hood.
b.Gas supply is connected properly with the proper gas type (natural or propane) with the correct size lines. Have the installer check for proper gas pressure and for gas leaks.
c.Water connected properly to the coupling at the rear of the unit.
d.Ensure drain plumbing is routed to the disposal area.
e.Perform
Refer to Chapter 2, Installation, page 2-1 — 2.8.
2. Ensure the product basket is properly placed in the heating vessel.
3.Perform Lighting Instructions.
4.Ensure drain valve is closed. Turn the computer
on by pressing the switch. Note: A decimal between digits 1 and 2 in either LED display indicates that the burners are lit.
5.Monitor operation of unit as the water reaches temperature. The computer will display as water temperature nears programmed setpoint.
Refer to Lighting Instructions, pages 3-1 — 3-2.
Refer to Chapter 3, Operating Instructions, page
6.When the water reaches the desired temperature, place product in the slotted product basket.
7.Remove product from the basket after the specified time.