3.7 Operating the FGP55 Rethermalizer

3.6 Programming the FGP55 CM-III.5 Computer (cont.)

SH2 will appear. Program the length of the second stir time as above being sure that the time entered is greater than that for stir time "1" or else is "0".

SH3 will appear. Program the length of the third stir time in the same manner as for stir times "1" and "2", being sure that the time entered is greater than that for stir time "2" or else is "0".

Manual background CAUTION

Remember: Stir time "2" must be greater than stir time "1" (or else be "0"). Stir time "3" must be greater than stir time "2" (or else be "0"). None of the stir times should be greater than the rethermalizing time entered in Step 6. If a stir time exceeds the rethermalizing time, the stir time will be ignored.

8.Manual background (Select Product) will again appear in the left display. If more products are to be programmed, return to Step 5 and follow all instructions to this point, repeating for each product.

9.When you complete your programming, lock in the whole program by pressing the Manual background switch.

3.7 Operating the FGP55 Rethermalizer

Turn the computer on by pressing the Manual background switch. Note: An illuminated dot between digits 1 and 2 in either LED display indicates that the burners are lit.

1.One of the following will be displayed:

a.°-Manual background: indicates the vessel temperature is 11ºF (6ºC) lower than the setpoint.

b.°-Manual background: indicates the vessel temperature is 11ºF (6ºC) higher than the setpoint.

c.Manual background(four dashes): indicates the vessel temperature is nearing setpoint.

d.Manual background: indicates a heating problem.

e.Manual background: indicates a problem with the computer temperature probe circuit.

2.Press a product button to initiate a rethermalizing cycle.

a.The previously programmed rethermalizing time will appear and the timer countdown will begin.

b.If stir times are programmed, the operator will be notified of the need to stir the product “X” seconds after the rethermalizing cycle has begun (X = amount of time programmed). An alarm will sound, the display will read Stir, and the LED in the product button will blink.

3–7

Page 24
Image 24
Frymaster operation manual Operating the FGP55 Rethermalizer, Programming the FGP55 CM-III.5Computer cont