D.TEST CONTROLLING FUNCTION
1.Press controller ON/OFF switch to ON (set point = 340°F/171°C).
2.Set
(a)RELAY POWER indicator (3) illuminates.
(b)Rotate VARIABLE knob (8 & 9) counterclockwise until controller indicates a temperature.
(c)Rotate VARIABLE knob (8 & 9) slowly clockwise until controller indicates DROP.
(d)Press Temperature button on controller. Controller should indicate a temperature from one (1) to (4) degrees +/- set point (340°F/171°C). If not, rotate the VARIABLE knobs (8 & 9) counterclockwise very slowly until HEAT indicators (2 & 4) cycles ON. DROP band is
(e)HEAT indicators (2 & 4) should now cycle ON and OFF very slowly.
E.TEST CONTROLLER HIGH LIMIT
1.Press controller ON/OFF switch to ON.
2.Set
(a)RELAY POWER indicator (3) illuminates.
(b)Controller displays “HOT”
(c)RELAY POWER indicator (3) is no longer illuminated.
(d)Turn off
F.TEST PROBE FAILURE MALFUNCTION
1.Press controller ON/OFF switch to ON.
2.Set
(a)RELAY POWER indicator (3) illuminates.
(b)Controller displays “HIGH LIMIT FAILURE” alternating with “DISCONNECT POWER” and the alarm sounding.
(c)RELAY POWER indicator (3) is no longer illuminated.
(d)Turn off
(e)Controller test is now complete.