CHAPTER 6: OPERATOR TROUBLESHOOTING

HEATED LANDING ZONE

CHAPTER 6: OPERATOR TROUBLESHOOTING

Symptom

 

Possible Cause

 

No power

 

Circuit breaker out

No computer display; no flow from

Low voltage

air tower

Bad fuse

 

Bad transformer

 

Hi-limit out

 

 

 

No flow from air tower

Bad latching relay

 

 

 

 

 

RTD probe has failed. Isolate failed component

 

 

by checking temperature of air and heater plate

After 20 minutes of operation

 

with the temperature display keys on the

 

computer. The plate temperature should be

computer display shows PROB

 

within ± 15°F of setpoint. The air heat should be

 

 

within ± 25°F of setpoint. If both temperatures are

 

 

good, the computer is likely bad.

 

 

 

After 20 minutes of operation

Plate heater, plate heater relay or RTD are faulty.

computer display shows HI

 

 

After 20 minutes of operation

Air heater, air heater relay or RTD are faulty

computer display shows LO

 

 