MPF50S SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 6: TROUBLESHOOTING/SERVICE PROCEDURES
6.4.3.1 Replace Motor
4.Remove four bolts securing the pump to the motor. Leave the plumbing connected to the pump. Use care not to damage the flex supply lines connected to the pump. Remove the pump gasket for reassembly.
5.Remove six screws securing the motor bracket from the bottom of the base. Support the motor with one hand when removing the screws. Pull the
6.Remove the cover plate to access the motor wiring. Splices or bombtails are needed for two connections. Rewire the replacement motor using the wiring diagram in Section 6.3.4.
7.Complete installation of replacement motor by reversing the above steps.
.
Remove six screws from the base bottom to remove the motor and motor bracket. Remove four bolts securing the motor to
Two connections require splices or bombtails (arrows).