Frymaster MPF50S Series manual Replace Motor/Pump, MPF50S SERIES PORTABLE FILTRATION SYSTEMS

Models: MPF50S Series

1 30
Download 30 pages 40.84 Kb
Page 23
Image 23
6.4.3 Replace Motor/Pump

MPF50S SERIES PORTABLE FILTRATION SYSTEMS

CHAPTER 6: TROUBLESHOOTING/SERVICE PROCEDURES

6.4.3 Replace Motor/Pump

1.Disconnect power cord from power supply.

2.Perform Step 2, Section 6.4.1. Remove two screws securing the handle brackets to the control panel (arrows). Do not remove the remaining handle-bracket screws. Remove remaining screws securing control panel to filter base. Lift the control panel from the base and work the switch panel through the control panel opening. Leave the switch panel wired and set aside, using care not to stretch and disconnect wiring. Remove control panel.

Remove these screws from handle brackets to remove control panel.

Remove screws illustrated to remove control panel. (Switch panel omitted for clarity.)

3.Remove cord-holder bracket and outer panels (see Step 3, Section 6.4.2 for reference).

Remove cord-holder bracket and outer panels.

6-7

Page 23
Image 23
Frymaster MPF50S Series Replace Motor/Pump, MPF50S SERIES PORTABLE FILTRATION SYSTEMS, Troubleshooting/Service Procedures