shows HI 2 BAD.

Problem

Probable Causes

Corrective Action

 

 

This is displayed only during a test

M2000 display

 

of the high-limit circuit and indicates

Computer in high-limit test mode.

that the high-limit has failed. DO

shows HI 2 BAD.

 

 

NOT OPERATE THE FRYER! Call

 

 

FASC.

M2000 display

 

 

shows PROBE

Damaged computer wiring harness

Call FASC

FAILURE with

or connector.

 

alarm sounding.

 

 

M2000 display

Drain valve not fully closed.

Press the ON/OFF switch off, close

shows IGN

 

the drain valve(s) completely, then

Failure

 

press the ON/OFF switch on.

with alarm

 

 

sounding. Heating

 

 

indicator is on, but

 

 

no heat.

 

 

M2000 display

 

 

shows

 

 

LOW TEMP,

A. Failed computer.

A. Call FASC.

heating indicator

 

 

 

cycles on and off

 

 

normally.

 

 

 

 

 

 

B. Damaged computer wiring

B. Call FASC.

 

harness.

 

 

M2000 display

 

 

shows IGN

 

Call FASC.

failure and

Failed computer.

alarm sounds, but

 

fryer operates

 

 

normally (false

 

 

alarm).

 

 

Computer will not

 

 

go into program

 

Call FASC.

mode or some

Failed computer.

 

buttons do not

 

 

actuate.

 

 

Heat indicator off

 

 

upon initial startup.

 

 

Display shows

Failed computer.

Call FASC.

or with alarm

 

 

sounding.

 

 

6-5