WARNING

To ensure the safe and efficient operation of the fryer and hood, the electrical plug for the 120-volt line, which powers the hood, must be fully engaged and locked in its pin and sleeve socket.

2.1.3 Australian Requirements

To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other relevant statutory regulations.

2.2Power Requirements

The three phase supply plug for the elements is rated at 60 amps, 250 VAC and is NEMA configuration L15-60P. The control and filter plug is rated at 20 amps, 120/208 VAC and is NEMA configuration L21-20P. Each fryer should have its cord for the element supply on an individual circuit as well as the control cord.

 

 

WIRE

MIN.

AWG

 

AMPS PER LEG

 

VOLTAGE

PHASE

SERVICE

SIZE

(mm2)

L1

 

L2

 

L3

208

3

3

6

(16)

39

 

39

 

39

240

3

3

6

(16)

34

 

34

 

34

480

3

3

8

(10)

17

 

17

 

17

220/380

3

4

6

(16)

21

 

21

 

21

240/415

3

4

6

(16)

20

 

20

 

21

230/400

3

4

6

(16)

21

 

21

 

21

230/400

3

4

6

(16)

25

 

25

 

25

France Only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTICE

If this appliance is permanently connected to fixed wiring, it must be connected by means of copper wires having a temperature rating of not less than 167°F (75°C).

DANGER

This appliance must be connected to a power supply having the same voltage and phase as specified on the rating plate located on the inside of the appliance door.

DANGER

All wiring connections for this appliance must be made in accordance with the wiring diagram(s) furnished with the appliance. Refer to the wiring diagram(s) affixed to the inside of the appliance door when installing or servicing this equipment.

2.3After Fryers Are Positioned At the Frying Station

DANGER

No structural material on the fryer should be altered or removed to accommodate placement of the fryer under a hood. Questions? Call the Frymaster Dean Service Hotline at 1-800-551-8633.

2-3

Page 13
Image 13
Frymaster BIRE14, MRE14 warranty Power Requirements