1.6 Adjusting the Pilot Flame

1.6 Adjusting the Pilot Flame

1.Remove the cover shown in the illustration below to access the pilot flame adjustment screw in the gas valve.

Pilot adjustment locations on CE gas valves (left) and non-CE gas valves (right).

2.Using a small, flat-tipped screwdriver, turn the pilot flame adjustment screw counterclockwise to increase the length of the flame or clockwise to decrease the length of the flame. Adjust the flame to a length of 1-½ inches (38 mm).

3.Reinstall the pilot flame-adjustment cover.

4.Five-tube millivolt fryers: Adjust the trailing pilot (adjustment valve located on the burner manifold) until a 1-½ inch (38 mm) flame is obtained.

1.7 Replacing Fryer Components

1.7.1 Replacing the Operating Thermostat

1.Drain the fryer and turn the gas off.

2.Remove the thermostat knob by pulling straight out on the knob with a firm, steady pull.

3.Disconnect the wires from the thermostat.

4.Remove the two mounting screws to release the thermostat control from its mounting bracket.

5.Remove the screws and clamp that secure the thermostat bulb to the frypot. Remove spring from bulb and reinstall on replacement thermostat bulb.