CHAPTER 3: FILTER PREPARATION

3.1 Assembling The Filter System

On initial installation and before each use, remove all loose parts from the filter, wash the filter pan and all accessories in hot, soapy water and dry thoroughly.

CHAPTER 3: FILTER PREPARATION WARNING!

Water or boil-out solution MUST not be allowed to drain into the filter pan or filter system. Irreversible damage will result if water is allowed into the system, and the warranty will be voided.

YPF95 Series portable filtration systems use a filter support grid, one sheet of filter paper and a hold-down ring to secure the filter paper in place.

See illustration for proper assembly.

1.Filter Pan Cover Front

2.Filter Pan Cover Rear

3.Hold-Down Ring

4.Filter Paper (one sheet)

5.Screen/Sana Grid

6.Filter Pan Assembly

2

3

1

4

5

3.1 Assembling The Filter System 6

A.First, place the Sana Grid in the bottom of filter pan.

B.Place one sheet of filter paper on top of the Sana Grid. Ensure the paper evenly covers the filter pan bottom.

C.Position the hold-down ring on top of the filter paper securely against the filter pan bottom, forming a tight seal.

D.Sprinkle 8 ounces of filter powder over the filter paper, distributing the powder as evenly as possible. If filtering a second frypot immediately after the first, add only 4 ounces of filter powder for the second filtering.

E.Place filter pan covers onto the filter pan assembly.

F.Position filter in the space between the two fryers. Lock the rear casters to prevent filter from moving out of position during the filtering process.