;In Case of 3-1/4"×10"Vertical Discharge

Mount the supplied 3-1/4"×10" rectangular duct joint on the top plate with 4 screws (2 pieces: removed in Step 4-1, the others: supplied).

Then attach the supplied soft tape around the duct joint.

Soft Tape

Duct Joint

;In Case of 7" Round Vertical Discharge

First, remove half-cut circular part of the top plate (duct knockout) using a hammer, pliers, etc.

Mount the 7" round duct joint removed in step (1) with 4 screws.

Then attach the supplied soft tape around the duct joint.

CAUTION: • Wear working gloves to avoid injury.

Do not apply excessive force when removing the knockout. The fan may be damaged.

;In Case of 3-1/4"×10"Horizontal Discharge

First, remove half-cut rectangular part of the rear plate (duct knockout) using a hammer, pliers, etc. Mount the supplied 3-1/4"×10" rectangular duct joint with 2 screws.

Then attach the supplied soft tape around the duct joint. To close the opening of the top plate, attach the supplied cover plate with 2 screws.

Hit dented points on the circular edge

Duct

Knockout

Hit dented points

on the rectangular edge

Duct

Knockout

Duct Joint

Soft Tape

7" Round

Duct Joint

Insert into the holes

Cover Plate

Engage with the notches

10