Serial Ports Submenu

The Serial Ports submenu allows you to select the port addresses and interrupts for the COM and IR ports.

Serial Ports

COM A I/O Settings:

( ) Disabled

(*)COM1, 3F8, IRQ 4 ( ) COM2, 2F*, IRQ 3 ( ) COM3, 3E8, IRQ 4 ( ) COM4, 2E8, IRQ 3

Infrared Port I/O Settings:

( ) Disabled

( ) IR1, 2100, IRQ 4

(*)IR2, 2200, IRQ 3 ( ) IR3, 2300, IRQ 4 ( ) IR4, 2400, IRQ 3

OKCancel

Figure 12. Serial Ports submenu

The Serial Ports submenu consists of two sections:

COM A I/O Settings

Infrared Port I/O Settings

The COM A I/O Settings section allows you to select which port address and interrupt will be used for COM port A. COM1,3F8,IRQ4 is the default setting. To select a different address and interrupt, use the up and down arrow to choose a different one.

The Infrared Port I/O Settings section allows you to select which port address and interrupt will be used for COM port B (infrared port). IR2,2200,IRQ3 is the default setting. To select a different address and inter- rupt, use the up and down arrow to choose a different one.

C o m p o n e n t s M e n u

LPT Port submenu

The LPT Port submenu allows you to select the port addresses and interrupts for the internal printer port.

 

 

LPT Port

 

Port Address

Port Definition

( )

None

( )

Standard AT (Centronics)

(*) LPT1, 378, IRQ 7

(*)

Bidirectional (PS/2)

( )

LPT2, 278, IRQ 5

( )

Enhanced Parallel (EPP)

( )

LPT3, 3BC, IRQ 7

( )

Extended Capabilities (ECP)

DMA Setting For ECP Mode

(*)DMA 0 ( ) DMA 1 ( ) DMA 2

OKCancel

Figure 13. LPT Port submenu

The LPT Port submenu consists of three sections:

Port Address

Port Definition

DMA Settings For ECP Mode

The Port Address section allows you to select which port address and interrupt will be used for the internal parallel (LPT) port. This is also known as the parallel port. LPT1,378,IRQ7 is the default setting. To select a different address and interrupt, use the up and down arrow to choose a different one.

The Port Definition section allows you to assign advanced capabilities to an attached device that supports the capabilities. Bidirectional (PS-2)is the default setting. To select one of the other selections --

Standard AT (Centronics), Enhanced

Parallel (EPP), or Extended Capabilities (ECP), use the up and down arrows to choose a different one.

Note that Extended Capabilities (ECP) must be selected in order to enable the DMA Setting For ECP Mode section.

The DMA Setting For ECP Mode section allows you to set the DMA channel for the parallel port if ECP Mode is selected in the Port Definition section. DMA 0 is the default setting.

11

Page 11
Image 11
Fujitsu A1010 manual Serial Ports Submenu, LPT Port submenu