Fujitsu AOU9RLS, ASU9RLS Swing Operation, Coil Dry Operation, En-11, To select SWING Operation

Models: AOU12RLS Heat & Cool Model (Reverse Cycle) ASU12RLS AOU9RLS ASU9RLS

1 20
Download 20 pages 3.22 Kb
Page 12
Image 12
SWING OPERATION

SWING OPERATION

Begin air conditioner operation before performing this procedure.

To select SWING Operation

Press the SWING button (Fig. 6 b11).

The SWING Display (Fig. 7 c8) will light.

Each time the SWING button is pressed, the swing operation will change in the following order.

To select SWING OperationPress the SWING button (Fig. 6 b11). Up/down swing operation To stop SWING OperationPress the SWING button and select STOP.COIL DRY OPERATION Left/right swing operation

Swing operation stops To select COIL DRY OperationTo cancel COIL DRY OperationOperation.En-11 Up/down/left/right swing operation Manual background

To stop SWING Operation

Press the SWING button and select STOP.

Airflow direction will return to the setting before swing was begun.

About Swing Operation

Up/down swing: Swing operation begins using the following range according to the current airflow direc- tion.

Airflow direction is 1–5 (for cooling, dry).

With the upper airflow-direction louver in the horizontal position, the lower airflow-direction louver moves (swings) to direct airflow to a wide area.

Airflow direction is 3–7 (for heating).

With the airflow-direction louvers set for down- ward or straight down airflow, airflow is directly mainly at the floor.

Left/right swing: The airflow-direction louvers move (swing) in the left/right airflow direction.

Up/down/left/right swing: The airflow-direction louvers move (swing) in both the up/down and left/right airflow directions.

The SWING operation may stop temporarily when the air conditioner’s fan is not operating, or when operating at very low speeds.

If the SET button(Vertical) is pressed during the up/ down swing operation, the up/down swing operation will stop and if the SET button(Horizontal) is pressed during the left/right swing operation, the left/right swing operation will stop.

COIL DRY OPERATION

The Indoor unit can be dried by pressing the COIL DRY button on the Remote Control Unit so as to avoid going moldy and restrain the breed of bacterium.

The COIL DRY Operation will operate for 90 minutes after pressing the COIL DRY button and it will stop automatically.

To select COIL DRY Operation

Press the COIL DRY button (Fig. 6 b4) during operation or when it stops.

The COIL DRY Indicator lamp (yellow) will light.(Then OPERATION Indicator lamp doesn’t light.)

The COIL DRY Display (Fig. 7 c4) will light. Then it will disappear after 10 seconds.

To cancel COIL DRY Operation

Press the START/STOP button (Fig. 6 b8) during COIL DRY

Operation.

When the COIL DRY Display

Light up: Press the START/STOP button once

Light off: Press the START/STOP button twice.

The COIL DRY Indicator lamp (yellow) (Fig.3 a7) will go out.

Then the operation stops.

About COIL DRY Operation

Press the COIL DRY button again during COIL DRY Operation, COIL DRY Opera- tion can be reset.

The COIL DRY Operation cannot get rid of the existed mould or bacterium, and it has no sterilization effect either.

En-11

Page 12
Image 12
Fujitsu AOU9RLS, ASU9RLS Swing Operation, Coil Dry Operation, En-11, To select SWING Operation, Press the SWING button b11