Fujitsu AOU12RLS Features And Functions, En-2, Inverter, Coil Dry Operation, Auto Changeover

Models: AOU12RLS Heat & Cool Model (Reverse Cycle) ASU12RLS AOU9RLS ASU9RLS

1 20
Download 20 pages 3.22 Kb
Page 3
Image 3
FEATURES AND FUNCTIONS

FEATURES AND FUNCTIONS

INVERTER

At the start of operation, a large power is used to bring the room quickly to the desired temperature. Afterwards, the unit automatically switches to a low power setting for eco- nomic and comfortable operation.

COIL DRY OPERATION

The Indoor unit can be dried by pressing the COIL DRY but- ton on the Remote Control Unit so as to avoid going moldy and restrain the breed of bacterium.

AUTO CHANGEOVER

The operation mode (cooling, dry, heating) is switched au- tomatically to maintain the set temperature, and the tem- perature is kept constant at all times.

MINIMUM HEAT OPERATION

The room temperature can be maintained at 50°F so as to prevent the room temperature from falling too far.

PROGRAM TIMER

The program timer allows you to integrate OFF timer and ON timer operations in a single sequence. The sequence can involve one transition from OFF timer to ON timer, or from ON timer to OFF timer, within a twenty-four hour period.

SLEEP TIMER

When the SLEEP button is pressed during Heating mode, the air conditioner’s thermostat setting is gradually lowered during the period of operation; during cooling mode, the thermostat setting is gradually raised during the period of operation. When the set time is reached, the unit automati- cally turns off.

WIRELESS REMOTE CONTROL UNIT

The Wireless Remote Control Unit allows convenient con- trol of air conditioner operation.

HORIZONTAL AIRFLOW: COOLING/

DOWNWARD AIRFLOW: HEATING

For cooling, use horizontal airflow so the cool air does not blow directly on the occupants in the room. For heating, use downward airflow to send powerful, warm air to the floor and create a comfortable environment.

OMNI-DIRECTIONAL AIR FLOW (SWING OPERATION)

Three-dimensional control over air direction swing is possi- ble through dual use of both an UP/DOWN air direction swing and RIGHT/LEFT air direction swing. Since UP/DOWN air direction flaps operate automatically according to the oper- ating mode of the unit, it is possible to set air direction based on the operating mode.

REMOVABLE OPEN PANEL

The indoor unit’s Open Panel can be removed for easy clean- ing and maintenance.

MILDEW-RESISTANT FILTER

The AIR FILTER has been treated to resist mildew growth, thus allowing cleaner use and easier care.

SUPER QUIET OPERATION

When the FAN CONTROL button is used to select QUIET, the unit begins super-quiet operation; the indoor unit’s air- flow is reduced to produce quieter operation.

POLYPHENOL CATECHIN AIR CLEANING FILTER

The polyphenol catechin air cleaning filter uses static elec- tricity to clean fine particles and dust in the air such as to- bacco smoke and plant pollen that are too small to see.

The filter contains catechin, which is highly effective against various bacteria by suppressing the growth of the bacteria adsorbed to the filter.

Note that when the air cleaning filter is installed, the amount of air produced decreases, causing a slight decrease in the indoor unit’s performance.

NEGATIVE AIR IONS DEODORIZING FILTER

It comprises pottery super micro particles which can pro- duce negative air ions having the effect of deodorizing and can absorb and remit the peculiar smell at home.

WIRED REMOTE CONTROL UNIT (OPTION)

The optional wired remote control unit (model No.: UTY-RNBYU) can be used.

When you use remote control unit, there are following different points as compared with using wireless remote control unit.

[The additional functions for wired ones]

Weekly timer

Temperature set back timer

[The restricted functions for wired ones]

ECONOMY

MAINTENANCE

And you can use both wired and wireless remote control unit simultaneously. (But function is limited)

[The restricted functions for wireless ones]

•SLEEP TIMER •TIMER •MIN. HEAT •COIL DRY

En-2

Page 3
Image 3
Fujitsu AOU12RLS manual Features And Functions, En-2, Inverter, Coil Dry Operation, Auto Changeover, Minimum Heat Operation