Fujitsu AWU36CX manual En-7, Operation, Auto Cooling Model, Auto * Auto Changeover, Heating

Models: AWU36CX

1 17
Download 17 pages 44.57 Kb
Page 8
Image 8
AUTO:

OPERATION

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

About Mode Operation

AUTO:

COOLING MODEL

When the room temperature is 4 °F higher than the set temperature, the mode will switch between Cooling and Drying.

During Drying mode operation, FAN set- ting is switched to LOW gentle cooling effect, and the room fan may stop rotat- ing temporarily .

If the mode automatically selected by the unit is not what you wish, see page 6 and select one of the mode operation (COOL, DRY, FAN).

Cooling Operation

Dry Operation

Thermostat control

4°F

Setting temperature

AUTO (* AUTO CHANGEOVER):

HEAT & COOL MODEL (Reverse cycle)

When AUTO CHANGEOVER operation is selected, the air conditioner selects the appropriate operation mode (Cooling or Heating) in response to your room’s temperature.

When AUTO CHANGEOVER operation first selected, the fan will operate at very low speed for about one minute, during which time the unit detects the room conditions and selects the proper operating mode.

When the air conditioner has adjusted your room’s temperature to near the ther- mostat setting, it will begin monitor operation. In the monitor operation mode, the fan will operate at low speed. If the room temperature subsequently changes, the air conditioner will once again select the appropriate operation (Heating, Cool- ing) to adjust the temperature to the value set in the thermostat. (The monitor operation range is ±4 °F relative to the thermostat setting.)

If the mode automatically selected by the unit is not what you wish, see page 6 and select one of the mode operation (HEAT, COOL, DRY, FAN).

*Heating:

Use to warm your room.

When Heating mode is selected, the air conditioner will operate at very low fan speed for about 3 to 5 minutes, after which it will switch to the selected fan set- ting. This period of time is provided to allow the indoor unit to warm up before beginning full operation.

When the room temperature is very low, frost may form on the outside unit, and its performance may be reduced. In order to remove such frost, the unit will automatically enter the defrost cycle from time to time. During Automatic De- frosting operation, the OPERATION indicator lamp (red) will flash, and the heat operation will be interrupted.

Cooling:

Use to cool your room.

Dry:

Use for gently cooling while dehumidifying your room.

You cannot heat the room during Dry mode.

During Dry mode, the unit will operate at low speed; in order to adjust room humidity, the indoor unit’s fan may stop from time to time. Also, the fan may operate at very low speed when detecting room humidity.

The fan speed cannot be changed manually when Dry mode has been selected.

Fan:

Use to circulate the air throughout your room.

* During Heating mode:

Set the thermostat to a temperature set- ting that is higher than the current room temperature. The Heating mode will not operate if the thermostat is set lower than the actual room temperature.

During Cooling/Dry mode:

Set the thermostat to a temperature set- ting that is lower than the current room temperature. The Cooling and Dry modes will not operate if the thermostat is set higher than the actual room temperature (in Cooling mode, the fan alone will oper- ate).

During Fan mode:

You can not use the unit to heat and cool your room.

En-7

Page 8
Image 8
Fujitsu AWU36CX En-7, Operation, Auto Cooling Model, Auto * Auto Changeover, HEAT & COOL MODEL Reverse cycle, Heating