TIMER OPERATION

Before using the timer function, be sure that the Remote Control Unit is set to the correct current time (See page 5).

To Use the ON timer or OFF timer

1

Press the START/STOP button (Fig. 6 L)

(if the unit is already operating, proceed to step 2).

 

The indoor unit’s OPERATION indicator lamp (green or red) (Fig. 3 5) will light.

2

Press the TIMER button (Fig. 6 J) to select the OFF

timer or ON timer operation.

 

Each time the button is pressed the timer function changes in the follow-

 

ing order:

 

 

 

 

 

 

sRESET

sOFF

 

sON

 

 

 

 

 

PROGRAM(OFF ON, OFF ON) t

 

 

 

 

 

 

The indoor unit’s TIMER indicator lamp (yellow) (Fig. 3 6) will light.

3

Use the SET TIME buttons (Fig. 6 H) to adjust the de-

sired OFF time or ON time.

 

 

 

To Cancel the Timer

Use the TIMER button to select “TIMER RESET”.

The air conditioner will return to normal operation.

To Change the Timer Settings

Perform steps 2 and 3.

To Stop Air Conditioner Operation while the Timer is Operating

Press the START/STOP button.

To Change Operating Conditions

If you wish to change the operating conditions (Mode, Fan Speed, Thermostat Setting), after making the timer setting, wait until the entire display reappears, then press the appropriate buttons to change the operating condition desired.

Set the time while the time display is flashing (the flashing will continue for about five seconds).

button: Press to advance the time.

button: Press to reverse the time.

About five seconds later, the entire display will reappear.

To Use the PROGRAM timer

1

Press the START/STOP button (Fig. 6 L)

(if the unit is already operating, proceed to step 2).

 

The indoor unit’s OPERATION indicator lamp (green or red) (Fig. 3 5) will

 

light.

2

Set the desired times for OFF timer and ON timer.

See the section “To Use the ON timer or OFF timer” to set the desired

 

mode and times.

 

About three seconds later, the entire display will reappear.

 

The indoor unit’s TIMER indicator lamp (yellow) (Fig. 3 6) will light.

3

Press the TIMER button (Fig. 6 J) to select the PRO-

GRAM timer operation (either OFF ON or OFF ON

will display).

The display will alternately show “OFF timer” and “ON timer”, then change to show the time setting for the operation to occur first.

The PROGRAM timer will begin operation. (If the ON timer has been selected to operate first, the unit will stop operating at this point.)

About five seconds later, the entire display will reappear.

To Cancel the Timer

Use the TIMER button to select “TIMER RESET”.

The air conditioner will return to normal operation.

To Change the Timer Settings

1.Follow the instructions given in the section “To Use the ON Timer or OFF Timer” to se- lect the timer setting you wish to change.

2.Press the TIMER button to select either OFF ON or OFF ON.

To Stop Air Conditioner Operation while the Timer is Operating

Press the START/STOP button.

To Change Operating Conditions

If you wish to change operating conditions (Mode, Fan Speed, Thermostat Setting), after making the timer setting, wait until the entire display reappears, then press the appropriate buttons to change the operat- ing condition desired.

About the PROGRAM timer

The PROGRAM timer allows you to integrate OFF timer and ON timer operations in a single sequence. The se- quence can involve one transition from OFF timer to ON timer, or from ON timer to OFF timer, within a twenty- four hour period.

The first timer function to operate will be the one set near- est to the current time. The order of operation is indi-

cated by the arrow in the remote control unit’s display (OFF ON, or OFF ON).

One example of PROGRAM timer use might be to have the air conditioner automatically stop (OFF timer) after you go to sleep, then start (ON timer) automatically in the morning before you rise.

About the ON timer

The timer function is designed to bring your room to a comfortable temperature by the set time; as a result, the unit automatically begins operation before the set time so that the room reaches the desired temperature by the time set on the timer.

The hotter it is in summer, or the colder it is in winter, the earlier that operation will begin.

*During Heating Operation ....... from 45 to 10 minutes be- fore set time.

During Cooling/Dry Operation ... from 20 to 10 minutes be- fore set time.

During Fan Operation

at the set time.

En-8

Page 9
Image 9
Fujitsu AWU36CX manual Timer Operation

AWU36CX specifications

The Fujitsu AWU36CX is a standout model in the realm of air conditioning, blending cutting-edge technology with impressive energy efficiency. Designed primarily for residential and small commercial applications, the AWU36CX exemplifies Fujitsu's commitment to delivering high-performance climate control solutions.

One of the prominent features of the AWU36CX is its inverter technology. This advanced system allows for precise control of the compressor speed, altering the cooling and heating capacity in real time according to the needs of the space. As a result, the AWU36CX can maintain a consistent indoor temperature while minimizing energy consumption. This not only enhances comfort but also translates into significant savings on energy bills over time.

The AWU36CX boasts a cooling capacity of 3.6 kW, making it suitable for medium-sized rooms or open-plan living spaces. On the heating front, this unit also provides effective warmth, ensuring year-round comfort. Its temperature range adaptability allows it to operate efficiently even in low outdoor temperatures, providing reliable heating during colder months.

Another key feature is its advanced filtration system. The AWU36CX is equipped with a multi-layer filter that effectively captures dust, allergens, and other airborne particles, promoting a healthier indoor environment. Users can expect improved air quality, making it an excellent choice for households with allergy sufferers or respiratory issues.

Fujitsu has also integrated smart technology into the AWU36CX. Users can enjoy convenient control via a remote or, in some cases, through smartphone applications. This allows for enhanced flexibility and ease of use, as well as the ability to program the unit to match their schedules, thereby optimizing energy consumption.

Furthermore, the AWU36CX is designed with quiet operation in mind. The unit functions at a low noise level, making it ideal for bedrooms or quiet spaces where noise could be disruptive. This characteristic makes it a favored choice among those who prioritize tranquility in their living environments.

In terms of build quality and design, the AWU36CX showcases a sleek and modern appearance. Its compact dimensions make it suitable for various installation settings, and it can seamlessly blend with contemporary interior aesthetics.

In conclusion, the Fujitsu AWU36CX stands out with its inverter technology, energy efficiency, advanced filtration, smart control options, quiet operation, and modern design. It is a reliable and effective air conditioning solution that balances performance and comfort, making it a popular choice for both homes and small businesses.