184
CHAPTER2 Dependence Functions
2.4.7.1 Measuring the Program Execution Cycle Count

This section explains the function of measuring the number of program execution

cycles.

Measurement Items

This function measures the number of program execution cycles or real-time. The measurement is
performed whenever a program is executed, and the measurement result displays the following values:
The measurement is performed whenever a program is executed, and the measurement result displays the
following two values:
- The number of execution cycles or real-time for the previous program execution
The maximum number of cycles that can be measured is 288,230,376,151,711,743 (2 to the power of
58 - 1).
- The total number of execution cycles or real-time after the previous clear operation
The maximum number of cycles that can be measured is 18,446,744,073,709,551,615 (2 to the power
of 64 - 1).
- Real-time measurement resolution
This depends on the execution cycle conversion frequency set for measurement unit. For details, refer
to "4.4.14.2 Performance (Emulator Debugger [MB2100-01])" of "SOFTUNE Workbench Operation
Manual".
Displaying Measurement Results
Either of the following methods can be used to display the measurement results.
• Dialog
- Time Measurement Dialog
For details, refer to "4.6.8 Time Measurement" of "SOFTUNE Workbench Operation Manual".
• Command
-SHOW TIMER
For details, refer to "4.27 SHOW TIMER" of "SOFTUNE Workbench Command Reference
Manual".
Clearing Measurement Results
Either of the following methods can be used to clear the measurement results.
• Dialog
- Time Measurement Clearing Dialog
For details, refer to "4.6.8 Time Measurement" of "SOFTUNE Workbench Operation Manual".
• Command
-CLEAR TIMER
For details, refer to "4.28 CLEAR TIMER" of "SOFTUNE Workbench Command Reference
Manual".