187
CHAPTER2 Dependence Functions
■Measuring ProcedureUse the following steps to measure the performance.
1. Specify the performance measuring interval.
2. Execute the measurement.
3. Display the measurement result.
Each of these steps can be executed in two methods: using GUI (window or dialog) and using only the
command. In both methods, the same measurement result is obtained.
Using GUI for measuring
1. Display the performance window.
- Select [View] - [Performance] menu.
For details, refer to Section "3.18 Performance Window" in "SOFTUNE Workbench Operation
Manual".
2. Specify the performance measuring interval.
- Right-click on the performance window, and select [Setup] from the pop-up menu. The performance
setting dialog appears.
Here, click the [Display Range] tab to specify the interval in which performance is to be measured.
For details, refer to Section "4.4.14 Performance" in "SOFTUNE Workbench Operation Manual".
3. Execute user programs.
4. Display the measurement result.
- Right-click on the performance window, and select [Refresh] from the pop-up menu. The
performance measurement result appears.
Using Command for Measuring
1. Specify performance events.
- Execute the SET EVENT command.
For details, refer to Section "3.15 SET EVENT" in "SOFTUNE Workbench Command Reference
Manual".
2. Specify the performance measuring interval.
- Execute the SET PERFORMANCE command.
For details, refer to Section "4.2 SET PERFORMANCE (type 2)" in "SOFTUNE Workbench
Command Reference Manual".
3. Execute user programs.
4. Display the measurement result.
- Execute the SHOW PERFORMANCE command.
For details, refer to Section "4.4 SHOW PERFORMANCE" in "SOFTUNE Workbench Command
Reference Manual".
■Ending the MeasurementThe performance measurement is ended in one of the following cases.
• The measuring count has reached 65535.
• A user program has stopped during measurement.