Chapter 1 Components
1.1 Controller Enclosure
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
20
Copyright 2012 FUJITSU LIMITED P3AM-5512-03ENZ0
■SAS model
Figure 1.14 Controller (SAS model)
●Part explanation
•LAN (RMT) port, LAN (MNT) port
These are the RJ-45 connectors to connect LAN cables. LAN (RMT) port is not used in the
EMEA&I region.
A single controller has one LAN (RMT) port and one LAN (MNT) port.
•SAS port (0 (left), 1 (right))
These are the miniSAS (SFF8088) connectors to connect miniSAS cables.
UNIT READY/
FAULT (green)
The controller is in normal status.
(orange) •The controller is performing the initial setup after the
power is turned on.
•The controller is in error status.
MASTER
(green)
The controller is set as a Master CM.
ACT
(green)
The controller is sending or receiving data via the LAN
port (for operation management).
LINK
(green)
•The link between the LAN port (for operation
management) and the destination has been
established.
•The link between the iSCSI port (host interface port)
and the destination has been established.
FAULT
(orange) •The controller is performing the initial setup after the
power is turned on.
•The iSCSI port (host interface port) is in error status.
LED name LED status Controller status
SAS port (0 (Left), 1 (Right))
SAS (HOST) LINKUP/FAULT LED
DI (OUT) port
PWC port
ACT LED
LINK LED
MASTER LED
UNIT READY/FAULT LED
LAN (RMT) port
DI (OUT) LINKUP LED
SCU STATUS LED
IDENTIFY LED
LAN (MNT) port