Appendix A Event Notification Message List
A.1 Message Format
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
89
Copyright 2012 FUJITSU LIMITED P3AM-5512-03ENZ0
Message 4 A comment that is set using the e-mail notification setting of ETERNUS Web GUI
or ETERNUS CLI is displayed.
5 A message that indicates the event is displayed.
Refer to "A.2 Message List" (page 93) for details.
6 The message event type and the event code that are separated by a blank are
displayed.
One of the following letters is output as an event type:
"P", "J", "M", "I", "R"
Event code is an 8-digit hexadecimal number according to the message.
Refer to "A.2 Message List" (page 93) for details.
7 The Severity of the event is displayed. One of the following items is displayed for
the message:
Error: indicates an error
Warning: indicates a warning
Information: indicates that information is provided
Test: indicates a test mail
8 The event serial number, which increases from the startup of the ETERNUS DX
Disk storage system, is displayed in the "x-yyyy" format.
x: Controller number (0 or 1)
yyyy: Serial number
The event serial number is reset when the ETERNUS DX Disk storage system is
turned on or restarted.
9 The time when the event occurred is displayed in the "Mmm dd hh:mm:ss yyyy"
format.
Mmm: Abbreviation of each month (Jan – Dec)
dd: Date. If the date is a single digit, "0" is output before the date number.
hh:mm:ss: "hh" indicates the hour (00 – 23), "mm" indicates minutes (00 – 59),
and "ss" indicates seconds (00 – 59).
yyyy: The year is display with four digits.
10 The detailed information of the event is displayed. For multiple process results,
each process result is displayed on a separate line.
Number Description