Appendix A Event Notification Message List
A.2 Message List
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
97
Copyright 2012 FUJITSU LIMITED P3AM-5512-03ENZ0
P 13SSMM0p2 1300MM0p-Controller Module#m(zz xxHz) FE Expander
Port#p Fault <pppppppppppp ssssssssss rrrrr>
These messages
are notified when
"Module was bro-
ken" is enabled for
Error Severity Level
in the event notifica-
tion setting.
They are not notified
during maintenance
operations.
CM FE Expander Port is disconnected.
SS: Component subtype
MM: CM module ID (10 – 11)
p: Port number (0 – 1)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version
P 1A00MM0p21A00MM0p-FC SFP Controller Module#m Port#p Fault
<pppppppppppppppp ssssssssssssssss rrrr
oooooooo>
SFP is disconnected.
MM: CM module ID (10 – 11)
p: Port number (0 – 1)
m: CM number (0 – 1)
pp...: Component number
ss...: Serial number
rr...: Version
oo...: Additional information
P 80SSdd0N2 8000dd0N-Disk Drive DE#dd-Disk#n(SAS xxxGB yykrpm
ccccccc) Fault <pppppppppppp ssssssssssss
rrrr>
These messages
are notified when
"Disk was broken" is
enabled for Error
Severity Level in the
event notification
setting.
They are not notified
during maintenance
operations.
3.5 inch Disk is disconnected.
SS: Component subtype
dd: DE-ID ("00" for a controller enclosure)
N: Disk slot number (0 – b (hexadecimal))
n: Disk slot number (0 – 11 (decimal))
xxx: Disk capacity (GB/TB)
yy: Disk speed
cc...: Disk information (RAID level or hot
spare (Spare))
pp...: Component number
ss...: Serial number
rr...: Version
Event type
and event
code
SNMP Trap Upper: Message
Remarks
Trap
No. TrapItemID
Trap
Sensor
Info
Lower: Description