Appendix 3 REPLACING CONSUMABLES
During its operation, the inside glass of the ADF becomes very
hot .
Before replacing the consumables, turn the scanner off and unplug the AC adapter from the outlet. Wait at least 15 minutes.
The illustration below demonstrates the locations of the replacement parts. Refer to "Chapter 5 Replacing Consumables"
■Replacing the Pad ASSY
■Consumables and Replacement Cycles
Below are specifications of consumable items and their recommended replacement cycles.
Description | Parts | Standard | |
Replacement | |||
Number | |||
| Cycle | ||
|
| ||
|
|
| |
|
|
| |
Pad ASSY | PA03360- | After 50,000 scans | |
| 0002 | or one year | |
|
|
| |
Pick roller | PA03360- | After 100,000 | |
| 0001 | scans or one year | |
|
|
|
To purchase consumables, contact the store where you purchased the scanner or an authorized FUJITSU scanner service provider.
The replacement cycles above are rough guidelines when using A4 or Letter woodfree or wood containing
paper 64 g/m2 (17 lb). This cycle varies according to the type of paper and how frequently the scanner is used and cleaned.
Use only the consumables specified
ATTENTION
by PFU Limited.
■Replacing the Pick Roller
Pick Roller Bushing
Pick Roller Shaft
Pick Roller Shaft
Pick Roller