Appendix 3 REPLACING CONSUMABLES

During its operation, the inside ￿￿￿￿￿￿￿ glass of the ADF becomes very

hot .

Before replacing the consumables, turn the scanner off and unplug the AC adapter from the outlet. Wait at least 15 minutes.

The illustration below demonstrates the locations of the replacement parts. Refer to "Chapter 5 Replacing Consumables" fi-5110C Operator’s Guide on the Setup CD-ROM.

Replacing the Pad ASSY

Consumables and Replacement Cycles

Below are specifications of consumable items and their recommended replacement cycles.

Description

Parts

Standard
Replacement
Number

 

Cycle

 

 

 

 

 

 

 

 

Pad ASSY

PA03360-

After 50,000 scans

 

0002

or one year

 

 

 

Pick roller

PA03360-

After 100,000

 

0001

scans or one year

 

 

 

To purchase consumables, contact the store where you purchased the scanner or an authorized FUJITSU scanner service provider.

The replacement cycles above are rough guidelines when using A4 or Letter woodfree or wood containing

paper 64 g/m2 (17 lb). This cycle varies according to the type of paper and how frequently the scanner is used and cleaned.

Use only the consumables specified

ATTENTION

by PFU Limited.

Replacing the Pick Roller

Pick Roller Bushing

Pick Roller Shaft

Pick Roller Shaft

Pick Roller

AP-5