Appendix2 DAILY CARE

￿￿￿￿￿￿￿

When operating the scanner, the ADF’s inside glass becomes very hot.

Before you clean inside the scanner, turn off its power and unplug the AC adapter from the outlet. Wait for at least 15 minutes.

Turn on the scanner when you clean the Feed rollers or Eject rollers.

Cleaning Materials
CleaningPartsRemarks
MaterialsNumber

 

 

 

 

 

 

 

Cleaner F1

PA03950-

1 bottle

 

0352

Moisten the cloth with

 

 

this fluid and wipe the

 

 

scanner clean. (*1)

 

 

 

Cleaning wipe

PA03950-

24 sheets per pack

 

0419

(*1)(*2)

 

 

 

Lint-free dry cloth

- Commercially available one

 

 

 

*1: For details about the cleaning materials, contact the FUJITSU scanner dealer where you purchased the scanner.

*2: Pre-moistened with Cleaner F1, Cleaning Wipes are used instead of moistened cloths.

Cleaning Method

The ADF must be cleaned with a lint-free cloth moistened with the Cleaner F1.

ATTENTION

It may take long before the cleaner vaporizes if a large quantity is used. When cleaning the scanner parts, dampen a cloth with modest quantities of the cleaner. In addition, wipe off the cleaner completely with a soft lint- free cloth to leave no residue on the surface of the cleaned parts.

Locations and Cycle for Cleaning
Part to cleanStandard Cleaning Cycle

 

 

 

 

Brake Roller

Clean these parts after every 5,000

 

sheets.

Pick roller

 

 

 

Feed rollers

 

 

 

Plastic rollers

 

 

 

Eject rollers

 

 

 

Glass

 

 

 

ATTENTION

The scanner must be cleaned more frequently if you scan any of the following type of sheets:

Documents of coated paper

Documents that are almost completely covered with printed text or graphics

Chemically treated documents such as carbonless paper

Documents containing a large amount of calcium carbonate

Documents written by pencil

Documents on which the toner is not fused sufficiently.

For details on cleaning the ADF, refer to section 4.3 "Clean- ing the ADF" of "fi-6140/fi-6240 Operator’s Guide" on the Setup CD-ROM.