(2)Activating the continuous operation test

Open the ADF and close it again. If no document is loaded on the ADF within five sec- onds after closing the ADF, the image scanner runs in flatbed mode. If documents are loaded on the ADF within five seconds after closing the ADF, the image scanner continu- ously feeds the document from ADF. Once the image scanner start reading documents in the flatbed mode, it does not feed documents from ADF even if documents are loaded on the ADF.

(3)Ending the test in flatbed mode

To stop the carrier movement in flatbed mode, open the ADF cover. If the ADF cover is opened, the POWER lamp starts blinking immediately after the carrier returns to the home position.

(4)Ending the test in ADF mode

If the ADF document hopper is empty, feeding documents from the ADF ends. To restart feeding, open the ADF cover and close it again. Then load documents on the ADF docu- ment hopper within five seconds after closing the ADF cover.

(5)LED status on error

If an error occurs during the test, the LED indicates as shown in table B.1.

If paper is jammed in the ADF, remove the jam and close the ADF cover. The CHECK lamp stops blinking about three seconds after closing the ADF cover. To feed the docu- ment from ADF, open and close the ADF cover.

Table B.1 LED at an error

Errors

POWER lamp

READ lamp

CHECK lamp

 

 

 

 

Paper jam

On

Off

Blink

 

 

 

 

Carrier unit error

Blink

Off

On

 

 

 

 

Front optical system

Blink

Off

Blink

error

 

 

 

 

 

 

 

Back optical system

Blink

Blink

On

error

 

 

 

 

 

 

 

Motor fuse failure

Blink

On

On

 

 

 

 

Lamp fuse failure

Blink

On

Blink

 

 

 

 

B – 2

Page 44
Image 44
Fujitsu M3093DE, M3093DG manual Table B.1 LED at an error