TABLE 7 Specific Issues and Workarounds Concerning Solaris (Continued)

CR ID

Description

Workaround

 

 

 

6522433 After the CPU hardware error occurred, the fmdump(1M) command on the domain may display an incorrect faulty component.

6527811 The showhardconf(8) on XSCF can not display PCI card information that is installed in External I/O Expansion Unit, if the External I/O Expansion Unit is configured using PCI hotplug.

6530178 DR addboard(8) command can hang. Once problem is observed, further DR operations are blocked. Recovery requires reboot of the domain.

6529714 Warning messages occur while trying to configure more than four X4447A-Z or X1027A-Z1 cards into one I/O Boat.

6530288 Ap_Id format may not be shown correctly by cfgadm(1M) command.

6530753 Some of the PCI slots in the External I/O Expansion Unit PCI slots are not displayed during a normal boot operation.

6531036 The error message network initialization failed can appear repeatedly after boot net installation.

6531668 System hangs when executing parallel hot plug operation with SP DR in suspend phase.

6532215 volfs or dscp service may fail when domain is booted.

svc:/platform/sun4u/dscp:default: Method "/lib/svc/method/svc-dscp start" failed with exit status 95.

svc:/system/filesystem/volfs:defaul

t:Method or service exit timed out. Killing contract 59.

Check system status on XSCF.

There is no workaround. When each PCI card in the External I/O Expansion Unit is configured using PCI hotplug, the PCI card information is displayed correctly.

There is no workaround.

This bug has been fixed in Solaris 10 8/07.

No workaround available at this time.

None available at this time.

This bug has been fixed in Solaris 10 8/07.

Use one of the following operations to display all of the PCI slots.

boot -r(at open boot prompt)

devfsadm -C(at Solaris prompt)

cfgadm (twice at Solaris prompt)

There is no workaround.

No workaround available at this time.

Restart the service if the failure is observed. To avoid the problem, issue the following commands.

#svccfg -s dscp setprop start/timeout_seconds=count: 300

#svccfg -s volfs setprop start/timeout_seconds=count: 300

#svcadm refresh dscp

#svcadm refresh volfs

24 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1060 • November 2007