MAP3147FC MAP3735FC DISK DRIVES PRODUCT/MAINTENANCE MANUAL
C141-E163-01EN
FOR SAFE OPERATION
Handling of This Manual
IMPORTANT NOTE TO USERS
Chapter 4 Installation Requirements
Preface
Chapter 2 Specifications
Chapter 5 Installation
Preface
APPENDIX A
Conventions for Alert Messages
Preface
CONVENTIONS USED IN THIS MANUAL
This page is intentionally left blank
Important Alert Items
Important Alert Messages
Important Alert Items
C141-E163
C141-E163
Important Alert Items
This page is intentionally left blank
Manual Organization
This page is intentionally left blank
REFERENCED STANDARDS
FIBRE CHANNEL PHYSICAL AND SIGNALING INTERFACE FC-PH
FIBRE CHANNEL PRIVATE LOOP SCSI DIRECT ATTATH FC-PLDA
This page is intentionally left blank
CONTENTS
Alternate block allocation
Contents
A.1 Interface FC-SCA Connector Signal Allocation
Illustrations
Contents
Figures
Contents
Tables
This page is intentionally left blank
CHAPTER 1 General Description
1.1 Standard Features 1.2 Hardware Structure 1.3 System Configuration
1.1 Standard Features
General Description
1.1 Standard Features
General Description
12 Automatic alternate block reassignment
1.2 Hardware Structure
1.2 Hardware Structure
Figure 1.1 FC model drives outer view
Disk/head configuration
General Description
1.3 System Configuration
1.3 System Configuration
Figure 1.3 Example of FC-AL system configuration
1 Loop configuration
General Description
2.1 Hardware Specifications 2.1.1 Model name and order number
CHAPTER 2 Specifications
2.1 Hardware Specifications
Table 2.1 Model names and order numbers
Specifications
2.1.2 Function specifications
Function specifications
2.1 Hardware Specifications
Seek time ms Seek Difference 2048 Cyl/div
5 This value indicates at ready mode
Environmental/power requirements
Specifications
2.1.3 Environmental specifications
C141-E163
2.1 Hardware Specifications
2.1.4 Error rate
2.1.5 Reliability
Specifications
The MTBF is defined as Operating time hours at all field sites MTBF=
2.1 Hardware Specifications
4 Data security at power failure
C141-E163
This page is intentionally left blank
3.1 Data Space 3.2 Logical Data Block Addressing
CHAPTER 3 Data Format
3.1.1 Cylinder configuration
3.3 Defect Management
Figure 3.1 Cylinder configuration
Data Format
3.1 Data Space
Zone layout and track capacity
Data Format
3.1.2 Alternate spare area
Figure 3.3 Alternate cylinder
3.1 Data Space
Figure 3.2 Spare area in cell
3.1.3 Track format
Data Format
Figure 3.4 Track format
3.1.4 Sector format
3.1 Data Space
Figure 3.5 Track skew/head skew
Figure 3.6 Sector format
Data Format
Each sector on the track consists of the following fields
Table 3.2 Format capacity
3.2 Logical Data Block Addressing
3.1.5 Format capacity
3.2 Logical Data Block Addressing
Data Format
1 Block address of user space
3.3 Defect Management
3.3 Defect Management 3.3.1 Defect list
3.3.2 Alternate block allocation
Figure 3.7 Alternate block allocation by FORMAT UNIT command
Data Format
C141-E163
Figure 3.8 Alternate block allocation by REASSIGN BLOCKS command
3.3 Defect Management
3-13
Data Format
3 Automatic alternate block allocation
Automatic alternate block allocation is made only once during the execution of one command. If second defective block is detected, the alternate block assignment processing for the first defective block is executed but the alternate block assignment processing for the second one is not executed and the command being executed terminates. However, the initiator can recover the twice error by issuing the same command again
3.3 Defect Management
This page is intentionally left blank
4.1 Mounting Requirements 4.1.1 External dimensions
CHAPTER 4 Installation Requirements
4.1 Mounting Requirements 4.2 Power Supply Requirements
4.3 Connection Requirements
Installation Requirements
Figure 4.1 External dimensions
4.1 Mounting Requirements
4.1.2 Mounting
Figure 4.2 IDD orientations 4.1.3 Notes on mounting
Installation Requirements
Figure 4.3 Mounting frame structure
Figure 4.4 Limitation of side-mounting
Table 4.1 Surface temperature check point
Figure 4.5 Surface temperature measurement points
4.1 Mounting Requirements
Installation Requirements
Figure 4.6 Service clearance area
4.2 Power Supply Requirements
4.2 Power Supply Requirements
Figure 4.7 Current waveform +12 VDC
Attenuation 40 dB or more at 10 MHz
Installation Requirements
5 Noise filter
Figure 4.8 AC noise filter recommended
4.3 Connection Requirements 4.3.1 Connector
Figure 4.9 Connector location 4.3.2 Interface connector
4.3 Connection Requirements
4-10
Installation Requirements
Figure 4.10 SCA2 type connector
C141-E163
5.4 Dismounting Drives
CHAPTER 5 Installation
5.1 Notes on Handling Drives 5.2 Setting 5.3 Mounting Drives
5.6 Spare Disk Drive
Installation
5.2.2 Mode settings
5.2 Setting
5.2 Setting 5.2.1 Loop ID setting
Motor start mode
Installation
5.3 Mounting Drives 5.3.1 Mounting procedures
5.4 Dismounting Drives
5.4 Dismounting Drives
Installation
C141-E163
5.5.1 Checking initial operation
5.5.2 Checking connection
Installation
Motor starts when power is turned on
Figure 5.1 Checking the IDD connection A
Motor starts by START/STOP command Executing time about 60 seconds
Figure 5.2 Checking the IDD connection B
Installation
5.5.3 Formatting
2 FORMAT UNIT command
Installation
5.5.4 Setting parameters
continued
Installation
5-14
C141-E163
C141-E163
5-15
absolute value
C141-E163
Installation
5-16
5.6 Spare Disk Drive
6.4 Troubleshooting Procedures
CHAPTER 6 Diagnostics and Maintenance
6.1 Diagnostics 6.2 Maintenance Information 6.3 Operation Check
6.1 Diagnostics 6.1.1 Self-diagnostics
Diagnostics and Maintenance
6.1 Diagnostics
Operation of self-diagnostics
Diagnostics and Maintenance
6.1.2 Test programs
6.2 Maintenance Information
6.2 Maintenance Information 6.2.1 Precautions
1 Preventive maintenance
Diagnostics and Maintenance
6.2.2 Maintenance requirements
Preventive maintenance such as replacing air filters is not required
6.2 Maintenance Information
3 Parts that can be replaced in the field
Diagnostics and Maintenance
6.2.3 Maintenance levels
6.2 Maintenance Information
6.2.4 Revision numbers
Figure 6.1 Revision label example
Diagnostics and Maintenance
Figure 6.2 Indicating revision numbers 6.2.5 Tools and test equipment
6.2.6 Tests
C141-E163
6.2 Maintenance Information
Figure 6.3 Test flowchart
6-11
6.3 Operation Check 6.3.1 Initial seek operation check
Diagnostics and Maintenance
6.3.3 Diagnostic test
6.3.2 Operation test
6.4.1 Outline of troubleshooting procedures
6.4 Troubleshooting Procedures
6.4 Troubleshooting Procedures
6.4.2 Troubleshooting with disk drive replacement in the field
Diagnostics and Maintenance
System-level field troubleshooting
Disk drive troubleshooting
6.4 Troubleshooting Procedures
6.4.3 Troubleshooting at the repair site
C141-E163
This manual does not cover troubleshooting at the factory level
Diagnostics and Maintenance
6.4.4 Troubleshooting with parts replacement in the factory
6.4.5 Finding possibly faulty parts
7.1 Error Analysis Information Collection 7.1.1 Sense data
CHAPTER 7 Error Analysis
7.1 Error Analysis Information Collection 7.2 Sense Data Analysis
7.1.2 Sense key, sense code, and subsense code
Error Analysis
Figure 7.1 Format of extended sense data
7.2 Sense Data Analysis
7.2.1 Error information indicated with sense data
7.2 Sense Data Analysis
Definition of sense data
C141-E163
Error Analysis
7.2.3 Sense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read error
7.2.2 Sense data 3-0C-03, 4-40-xx, 4-44-xx, and 4-C4-xx
APPENDIX A Connector Signal Allocation
A.1 Interface FC-SCA Connector Signal Allocation
FC-SCA connector CN1
Connector Signal Allocation
A.1 Interface FC-SCA Connector Signal Allocation
Table A.1
FC Device
Glossary
Command
Initiator INIT
Glossary
Target TARG
Acronyms and Abbreviations
Acronyms and Abbreviations
Index
Index
Index
This page is intentionally left blank
1, Place des Etats-Unis, SILIC 310, 94588 Rungis Cedex, FRANCE
This page is intentionally left blank
READER’S COMMENT FORM