Fujitsu MAP3735FC, MAP3147FC Sense Data Analysis, Error information indicated with sense data

Models: MAP3735FC MAP3147FC

1 114
Download 114 pages 6.14 Kb
Page 97
Image 97
7.2 Sense Data Analysis

7.2 Sense Data Analysis

7.2Sense Data Analysis

7.2.1Error information indicated with sense data

Subsection 7.2.2 onwards explain troubleshooting using sense data.

Table 7.1 lists the definition of sense data. For details of sense data, refer to the Fibre Channel Interface Specifications.

 

 

 

 

Table 7.1

Definition of sense data

 

 

 

 

 

 

 

Sense data

 

 

 

 

 

 

 

 

 

Sense

Sense

 

Sub

 

Definition

key

Code

 

Sense

 

 

 

 

 

Code

 

 

 

 

 

 

 

00

00

 

00

Operation was normal.

 

 

 

 

 

3

0C

 

03

A write to a disk terminated abnormally.

 

 

 

 

 

4

32

 

01

Failed to update the defect list due to a disk medium write error, etc.

 

40

 

xx

An error occurred in power-on self-diagnosis.

 

44

 

xx

A hardware error occurred inside IDD.

 

C4

 

xx

A drive error occurred.

 

 

 

 

 

1

1x

 

xx

A disk read error occurred.

3

1x

 

xx

A disk read error occurred.

 

 

 

 

 

E

1D

 

00

Data discrepancy found by VERIFY command byte check.

 

 

 

 

 

5

2x

 

xx

A SCSI error, such as an invalid operation code, occurred.

 

3D

 

00

The Reserve bit of the IDENTIFY message was set to 1.

B

47

 

00

A CRC error occurred in the fibre channel loop.

B

49

 

00

An unmounted or inappropriate message was received.

B

4D

 

xx

Before completion of a command, a command with the same tag

 

 

 

 

number was issued.

B

4E

 

00

An overlap command was issued.

 

 

 

 

 

 

C141-E163

7-3

Page 97
Image 97
Fujitsu MAP3735FC, MAP3147FC Sense Data Analysis, Error information indicated with sense data, Definition of sense data