Fujitsu MAP3147NC/NP, MAP3735NP manual Operation Check Initial seek operation check, Operation test

Models: MAP3735NP MAP3367NC MAP3735NC/NP MAP3367NC/NP MAP3147NC/NP MAP3367NP

1 130
Download 130 pages 29.89 Kb
Page 108
Image 108

6.3Operation Check

6.3.1Initial seek operation check

If an error is detected during initialization by the initial seek operation check routine at power-on, the LED on the front panel blinks. The spindle motor of the disk drive then stops, and the disk drive is unusable.

For an explanation of the operation check before the initial seek, refer to the Section 5.6.

6.3.2Operation test

While the host computer is processing data, the IDD monitors disk drive operation including data processing, command processing, and seek operations. If the IDD detects an error, the IDD posts the error to the INIT. The INIT then posts the error to the user.

The user may detect an intermittent or nonfatal error such as abnormal noise, abnormal odor, or very slow operation.

An error posted in an operation test must be investigated. Replace the disk drive to see whether the error was caused by the disk drive.

Often, errors posted in an operation test may be caused by the host system. Possible causes include insufficient power capacity, loose cable connection, insufficient timing or insufficient mechanical play, and problems related to other systems.

If an operation error is detected by the error detection circuit of the disk drive, an interrupt occurs. The interrupt is posted to the MCU on the PCA. The MCU stops the currently processed command, and causes the CHECK CONDITION status to post the error to the INIT.

When receiving the CHECK CONDITION status, the INIT issues a REQUEST SENSE command to collect detailed information about the error. The INIT then issues a REZERO UNIT command to return the read/write head to track 00. In normal processing, the IDD itself or INIT determines how to handle the error (processing retry or stop).

To analyze the error posted in the operation test, reconstruct the conditions in which the error occurred. Then, start troubleshooting the whole host system by replacing the disk drive.

6.3.3Diagnostic test

The diagnostic test is executed to find a faulty subassembly in a faulty disk drive, or to check disk drive performance. This test is usually a combination of specific disk drive functions or group of functions. This test may be executed using a different host computers or test equipment and away from the environment where the error first occurred.

To analyze the error posted in the diagnostic test, reconstruct the conditions in which the error occurred. Then, look for a possibly faulty subassembly or part of the disk drive.

The procedures to be used in this test depend largely on the type of test equipment used, and are not covered by this manual.

6-12

C141-E166

Page 108
Image 108
Fujitsu MAP3147NC/NP, MAP3735NP, MAP3735NC/NP Operation Check Initial seek operation check, Operation test, Diagnostic test

MAP3735NP, MAP3367NC, MAP3735NC/NP, MAP3367NC/NP, MAP3147NC/NP specifications

Fujitsu's MAP3147NC/NP, MAP3367NC/NP, and MAP3735NC/NP hard disk drives represent a robust solution for businesses seeking reliable data storage options. These models are part of Fujitsu’s extensive line of high-performance hard drives that cater to various organizational needs, from servers to high-capacity data storage systems.

One of the standout features of these hard drives is their speed. The MAP3147NC/NP operates at a spindle speed of 10,000 RPM, ensuring rapid data access and retrieval. This speed is essential for environments requiring quick data transactions, making it suitable for enterprise-level databases and high-performance computing applications.

The capacity range across these models is designed to meet varying storage requirements. The MAP3147NC offers 147 GB, while the MAP3367NC provides 67 GB, and the MAP3735NC boasts a generous capacity of 35 GB. This diversity allows organizations to select the drive that best fits their data storage and performance needs while maintaining a scalable storage solution.

In terms of technology, the drives incorporate advanced features such as Serial Attached SCSI (SAS) interface, which enhances data throughput and reliability compared to traditional Parallel SCSI interfaces. SAS technology enables these drives to support multiple device connections while ensuring high-performance throughput, essential for modern enterprise environments.

The drives employ a 64 MB cache, providing a significant performance boost by allowing for quicker access to frequently used data. This capability improves overall system responsiveness, especially in applications requiring high input/output operations per second (IOPS).

Moreover, the MAP3147NC/NP, MAP3367NC/NP, and MAP3735NC/NP series are designed with data integrity in mind. They include features such as Error Correction Code (ECC) and background error scanning, which work together to maintain the integrity of stored data and minimize the risk of data loss.

In conclusion, Fujitsu’s MAP3147NC/NP, MAP3367NC/NP, and MAP3735NC/NP hard disk drives provide a blend of performance, capacity, and reliability. With their fast spindle speeds, robust data throughput via SAS technology, and enhanced cache memory, these drives are ideal for enterprises requiring durable and efficient data storage solutions in high-demand environments. As organization needs evolve, these drives offer scalability and reliability to support diverse applications and workloads.