Specifications

2.1.2Function specifications

Table 2.2 shows the function specifications of the IDD.

 

 

 

 

 

Table 2.2

Function specifications

 

 

 

 

 

 

 

 

 

 

 

Item

 

Specification

 

 

 

 

 

 

 

 

 

MAS3735FC

 

MAS3367FC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Formatted capacity/device (*1)

 

73.49 GB (*6)

 

36.77 GB (*6)

 

 

 

 

 

 

 

 

Number of disks

 

4

 

2

 

 

 

 

 

 

 

 

Number of heads

 

8

 

4

 

 

 

 

 

 

 

 

Number of cylinders (*2)

 

27,094

 

27,150

 

 

 

 

 

 

 

Formatted capacity/track (B)

 

285,696 to 360,960

 

 

 

 

 

 

 

Number of rotations min-1(rpm)

 

15,000 ± 0.2%

Average latency time

 

2.00 msec

 

 

 

 

 

 

 

 

Seek time (*3)

 

Track to Track

 

0.3 ms/0.5 ms

 

Average

 

3.3 ms/3.8 ms

(Read/Write)

 

 

 

 

 

 

8.0 ms/9.0 ms

 

 

 

Full stroke

 

 

 

 

 

 

 

 

Start/stop time

Start time

 

30 s typ. (60 s max.)

(*4)

 

 

Stop time

 

30 s typ.

 

 

 

 

 

 

 

Recording mode

 

32/34 MEEPRML

 

 

 

 

 

 

 

 

External

 

 

Height:

 

25.4 mm

 

 

Width:

 

101.6 mm

dimensions

 

 

 

 

 

Depth:

 

146.0 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight (max)

 

 

 

 

0.80kg

 

 

 

 

 

 

Power consumption (*5)

 

13.0 W

 

10.2 W

 

 

 

 

 

 

 

 

 

Interface

 

 

 

 

Cable length:

30 m max

 

 

 

 

 

Data

 

Disk drive

 

93.11 to 118.22 MB/s

transfer

 

 

 

 

 

 

 

 

 

FC-AL

 

212.5 MB/s max.

rate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Logical data block length

 

512 to 528 byte (Fixed length)

 

 

 

 

 

 

 

 

 

 

 

 

FC-PLDA (NCITS TR-19),

 

Command specification

FC-PH (ANSI X3.230-1994), FC-PH-2 (ANSI X3.297-1996),

 

 

 

 

 

FC-AL (ANSI X3.272-199X), SCSI-FCP (ANSI X3.269-199X)

 

 

 

 

 

 

Data buffer

 

 

 

32 MB FIFO ring buffer (*7)

 

 

 

 

Acostic noise (Ready)

 

3.6 Bels typ. (4.1 Bels max.)

 

 

 

 

 

 

 

 

 

(*1) The formatted capacity can be changed by changing the logical block length and using spare sector space. See Chapter 3 for the further information. The formatted capacity listed in the table is an estimate for 512 bytes per sector.

(*2) The number of user cylinders indicates the max., and includes the alternate cylinder. The number of user cylinders and alternate cylinders can be specified at format of the IDD.

(*3) The positioning time is as follows:

2-2

C141-E198

Page 30
Image 30
Fujitsu MAS3367FC, MAS3735FC manual Specifications, Function specifications, 32/34 Meeprml, Fc-Al, FC-PLDA Ncits TR-19