Specifications

Note:

The MTBF is defined as:

Operating time (hours) at all field sites

MTBF=

The number of equipment failures from all field sites

Failure of the equipment means failure that requires repair, adjustments, or replacement. Mishandling by the operator, failures due to bad environmental conditions, power trouble, host system trouble, cable failures, or other failures not caused by the equipment are not considered.

(2)Mean Time To Repair (MTTR)

MTTR is the average time taken by a well-trained service mechanic to diagnose and repair a drive malfunction. The drive is designed for a MTTR of 30 minutes or less.

(3)Service life

The service life under suitable conditions and treatment is as follows.

The service life is depending on the environment temperature. Therefore, the user must design the system cabinet so that the average DE surface temperature is as possible as low.

DE surface temperature: 40°C or less

5 years

DE surface temperature: 41°C to 45°C

4.5 years

DE surface temperature: 46°C to 50°C

4 years

DE surface temperature: 51°C to 55°C

3.5 years

DE surface temperature: 56°C to 60°C

3 years

DE surface temperature: 61°C and more

Strengthen cooling power so that DE surface

 

 

temperature is 60°C or less.

Even if the IDD is used intermittently, the longest service life is 5 years.

Note:

The "average DE surface temperature" means the average temperature at the DE surface throughout the year when the IDD is operating.

2-6

C141-E198

Page 34
Image 34
Fujitsu MAS3367FC, MAS3735FC manual Mtbf=