Manuals
/
Fujitsu
/
Computer Equipment
/
Computer Drive
Fujitsu
manual
MAS3735FC MAS3367FC Disk Drives PRODUCT/MAINTENANCE Manual
Models:
MAS3735FC
MAS3367FC
1
1
114
114
Download
114 pages
1.31 Kb
1
2
3
4
5
6
7
8
<
>
Troubleshooting
Specs
Install
Test flowchart
Connector Signal Allocation
Error rate
Maintenance
Disk/head configuration
Diagnostics Self-diagnostics
10 SCA2 type connector
Page 1
Image 1
C141-E198-02EN
MAS3735FC
MAS3367FC
DISK DRIVES
PRODUCT/MAINTENANCE MANUAL
Page 2
Page 1
Image 1
Page 2
Contents
MAS3735FC MAS3367FC Disk Drives PRODUCT/MAINTENANCE Manual
For Safe Operation
Revision History
This page is intentionally left blank
Overview of Manual
Preface
Conventions for Alert Messages
Preface
C141-E198 Iii
This page is intentionally left blank
Important Alert Messages
Important Alert Items
Important Alert Items
C141-E198 Vii
This page is intentionally left blank
Manual Organization Product
Maintenance Manual
Fibre Channel Physical and Signaling INTERFACE-2 FC-PH-2
Fibre Channel Physical and Signaling Interface FC-PH
Fibre Channel Arbitrated Loop FC-AL
Fibre Channel Plotocol for Scsi SCSI-FCP
Contents
Contents
Installation
Appendix a Connector Signal Allocation
Figures
Tables
This page is intentionally left blank
General Description
Standard Features Hardware Structure System Configuration
General Description
Standard Features
Standard Features
General Description
FC model drives outer view
Hardware Structure
MAS3735FC MAS3367FC
Disk/head configuration
Example of FC-AL system configuration
System Configuration
General Description
Hardware Specifications Model name and order number
Hardware Specifications
Model names and order numbers
MAS3735FC
Function specifications
Specifications
32/34 Meeprml
FC-AL
Hardware Specifications
Environmental/power requirements
Environmental specifications
Iops
Reliability
Error rate
MTBF=
Hardware Specifications
This page is intentionally left blank
Data Space Logical Data Block Addressing Defect Management
Cylinder configuration
Data Space
Data Format
Zone layout and track capacity
Data Space
Alternate spare area
Track format
Data Space
Msec Servo frame = 211 zone 0 ~ 266 zone
Sector format
Track skew/head skew
Data Format
Format capacity
Logical Data Block Addressing
Data Format
Defect Management Defect list
Defect Management
Alternate block allocation
Alternate block allocation by Format Unit command
Alternate block allocation by Reassign Blocks command
Write Write Extend
Defect Management
This page is intentionally left blank
Mounting Requirements External dimensions
Installation Requirements
Installation Requirements
Mounting
Mounting Requirements
Mounting frame structure
HDC
Surface temperature check point
MPU
Service clearance area
Current waveform +12 VDC
Power Supply Requirements
AC noise filter recommended
Connection Requirements
Connection Requirements Connector
10 SCA2 type connector
Installation
Installation
Setting Loop ID setting
Setting
Mode settings
Motor start mode
Mounting Drives Mounting procedures
Dismounting Drives
Installation
Checking connection
Checking the IDD connection a
Checking the IDD connection B
Formatting
C141-E198
Setting parameters
Arre
Awre
Arre Awre PER
Xffff
Disc
Xxxx
Read/write
Self-diagnostic functions
Diagnostics Self-diagnostics
Diagnostics and Maintenance
Diagnostics
Test programs
Maintenance Information Precautions
Maintenance Information
Maintenance requirements
Maintenance Information
Maintenance levels
Revision label example
Revision numbers
Tests
Indicating revision numbers Tools and test equipment
Test flowchart
Operation Check Initial seek operation check
Diagnostic test
Operation test
Troubleshooting with disk drive replacement in the field
Troubleshooting Procedures
System-level field troubleshooting
Disk drive troubleshooting
Troubleshooting at the repair site
Finding possibly faulty parts
Troubleshooting with parts replacement in the factory
Error Analysis Information Collection Sense data
Error Analysis Information Collection Sense Data Analysis
Sense key, sense code, and subsense code
ILI
Error Analysis
LSB
Sksv
Definition of sense data
Sense Data Analysis
Sense data 3-0C-03, 4-40-xx, 4-44-xx, and 4-C4-xx
Sense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read error
Appendix a Connector Signal Allocation
Connector Signal Allocation
Glossary
Target Targ
Glossary
Acronyms and Abbreviations
RSV
Acronyms and Abbreviations
ECC
Bcrc
Index
Mode SELECT/MODE
Mtbf Mttr
PAD
C141-E198 IN-3
This page is intentionally left blank
Fujitsu Canada INC
This page is intentionally left blank
READER’S Comment Form
This page is intentionally left blank
Top
Page
Image
Contents