Fujitsu MAV2073RC, MAV2036RC manual Sense data 3-0C-03, 4-40-xx, and 4-C4-xx

Models: MAV2073RC MAV2036RC

1 92
Download 92 pages 15.53 Kb
Page 80
Image 80

Error Analysis

7.2.2Sense data (3-0C-03), (4-40-xx), and (4-C4-xx)

Sense data (3-0C-03), (4-40-xx), and (4-C4-xx) indicate one of the following:

A target sector could not be detected using the sector counter.

A seek process overran the specified time.

A write to a disk terminated abnormally.

An error occurred in power-on self-diagnosis.

A drive error occurred.

The symptoms above are generally caused by an error in a PCA or DE.

7.2.3Sense data (1-1x-xx), (3-1x-xx) and (E-1D-00): Disk read error

If sense data (1-1x-xx), (3-1x-xx) or (E-1D-00) occurs frequently in a specific block of a disk, there is disk damage that was not recorded in the media defect list. In this case, assign an alternate block to the error-detected block using a REASSIGN BLOCKS command. For an explanation of the REASSIGN BLOCKS command, refer to Subsection 4.3.2 “REASSIGN BLOCKS (07)” of the Fibre Channel Interface Specifications.

If this error occurs in different blocks, a PCA or DE is faulty.

7.2.4Sense data (4-44-xx), (5-2x-xx), (B-44-xx), (B-47-xx), (B-4B-xx) and (B-4E-00): interface error

Sense data (4-44-xx, (5-2x-xx), (B-44-xx), (B-47-xx), (B-4B-xx) and (B-4E-00) indicates one of the following symptoms:

An invalid or unsupported command was issued, or invalid or unsupported parameters were specified.

An interface error occurred.

A hardware error occurred inside HDD.

If this error occurs, the PCA or the interface is faulty.

7-4

C141-E219

Page 80
Image 80
Fujitsu MAV2073RC manual Sense data 3-0C-03, 4-40-xx, and 4-C4-xx, Sense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read error