Interface

(12) STANDBY (X’96’ or X’E2’)

Upon receipt of this command, the device enters the standby mode. If the device has already spun down, the spin-down sequence is not implemented.

If the Sector Count field has a value other than "0," the APS timer is set when the command is received. In this event, the device enters the command waiting state, and the timer starts to count down. If a command is not received within the period specified as the APS timer value, the device automatically enters Standby mode. If the Sector Count field value is "0" the APS timer is disabled when the command is received.

Under the standby mode, the spindle motor is stopped. Thus, when the command involving a seek such as READ SECTOR(s) command is received, the device processes the command after driving the spindle motor.

Error reporting conditions

(1)A SATA communication error occurred (ST = 51h, ER = 14h).

At command issuance (Shadow Block Registers setting contents)

CM

 

 

 

X’96’ or X’E2’

 

 

 

 

 

 

 

 

DH

x

x

x

x

 

xx

 

 

 

 

 

 

 

CH

 

 

 

xx

 

CL

 

 

 

xx

 

SN

 

 

 

xx

 

SC

 

 

 

Period of timer

 

FR

 

 

 

xx

 

 

 

 

 

 

 

 

At command completion (Shadow Block Registers contents to be read)

ST

 

 

 

Status information

 

 

 

 

 

 

 

 

 

DH

x

x

x

 

x

 

xx

 

 

 

 

 

 

 

 

CH

 

 

 

 

xx

 

CL

 

 

 

 

xx

 

SN

 

 

 

 

xx

 

SC

 

 

 

 

xx

 

ER

 

 

 

Error information

 

 

 

 

 

 

 

 

 

5-50