30 SPARC Enterprise T5440 Server Administration Guide • July 2009
2. At the ILOM -> prompt, type:
The system is set to run full POST diagnostics on system reset.
3. To return to your normal diagnostic settings after running POST, type:
Related Information
■“Clearing Faults” on page 33
■“Bypassing Minor Faults” on page 31
■“Managing Devices” on page 34
■“Locate the System” on page 30
▼Locate the System1. Log in to ILOM.
See “Log In to ILOM” on page 28.
2. To easily find your system in a data center or server room, use the Locator LED
as described below.
■To turn on the Locator LED, fromthe ILOM -> prompt, type:
■To turn offthe Locator LED, from the ILOM -> prompt, type:
■To display the state of the locator LED, fromthe ILOM -> prompt, type:
For more information on LEDs, see your server’s service manual.
Related Information
■“Configure a Device Manually” on page 35
■“Clear Component Fault Messages” on page 34
-> set /SYS keyswitch_state=diag
-> set /SYS keyswitch_state=normal
-> set /SYS/LOCATE value=Fast_Blink
-> set /SYS/LOCATE value=off
-> show /SYS/LOCATE