Colour monitor 19P2

Preset operating modes

The picture position and size have been set to optimum values at the factory for the i operating modes listed above. Depending on the screen controller used, it may be

necessary to adjust the display position and size. In this case, you can change and save the settings (see "Operation of the monitor").

Horizontal frequency

Refresh rate

Screen resolution

 

 

 

 

31.5 kHz ± 0.5 kHz

60 Hz ±

2 Hz

640 x 480

31.5 kHz ± 0.5 kHz

70 Hz ±

2 Hz

720 x 400

50,6 kHz ± 0.5 kHz

100 Hz ±

2 Hz

640 x 480

53.7 kHz ± 0.5 kHz

85 Hz ±

2 Hz

800 x 600

63.0 kHz ± 0.5 kHz

100 Hz ±

2 Hz

800 x 600

68.7 kHz ± 0.5 kHz

85 Hz ±

2 Hz

1024 x 768

80.8 kHz ± 0.5 kHz

100 Hz ±

2 Hz

1024 x 768

91.2 kHz ± 0.5 kHz

85 Hz ±

2 Hz

1280 x 1024

93.1 kHz ± 0.5 kHz

100 Hz ±

2 Hz

1152 x 864

 

 

 

 

For ergonomic reasons we recommend a refresh rate of at least 75 Hz and a maximum resolution of 1024 x 1280 pixels.

Pin assignment D-SUB (15-pin)

5 1

6

10

15 11

Pin

Meaning

 

 

1

Red video input

 

 

2

Green video input / Sync. on green

 

 

3

Blue video input

 

 

4

Monitor ground

 

 

5

DDC Return

 

 

6

Red video ground

 

 

7

Green video ground

 

 

8

Blue video ground

 

 

Pin

Meaning

 

 

9

5 V for DDC

 

 

10

Logic ground

 

 

11

Monitor ground

 

 

12

DDC data (SDA)

 

 

13

H. sync (H/V comp. Sync.)

 

 

14

V. sync

 

 

15

DDC Clock

 

(SCL)

 

 

A26361-K713-Z100-1-5E19

English - 19

Page 27
Image 27
Fujitsu Siemens Computers 19P2 manual Preset operating modes, Pin assignment D-SUB 15-pin, Pin Meaning