2.6 Changing AC Power Specification

To change AC power specification from 100 VAC to 220 VAC and vice versa, change fuse and jumper wire settings and adjust the overvoltage detection circuit, following the instructions in this section.

Processor unit

Add or remove jumper connector P108 from the PWR board 03P9339 and change the fuse in the processor unit according to ship's mains. Then, adjust the overvoltage detection circuit, the pro- cedure for which is shown on the next page.

Note: When switching from 220 VAC to 100 VAC, construct a jumper connector locally, referring to the illustration on the next page. (VH8 connector housing is to be plugged into J108.)

Power supply

Fuse

Jumper connector P108

 

 

 

100 VAC

10A

Necessary

 

 

 

220 VAC

5A

Unnecessary

 

 

 

Cover of PWR board

Fuse

TB1

PWR board

Upper part of processor unit (SPU assembly omitted)

Processor unit, inside view

2-16

Page 40
Image 40
Furuno FAR-2157-D, FAR-2157-BB Changing AC Power Specification, Processor unit, Power supply Fuse Jumper connector P108