Fabricating HV cable TYPCY-1.5 and power cable TYPCY-2.5

1.Unfasten the gland nut for the HV cable and remove gasket, flat washers (3 pcs.) and gland cap. (The gland cap may be discarded.)

2.Fabricate the HV cable as shown below.

 

20 mm

Armor

 

5 mm

 

 

Sheath

Sheath

 

600 mm

FV2-4

 

 

Vinyl

Armor

Conductor

sheath

 

S = 1.50 mm2

 

φ = 1.56 mm

 

 

 

 

SECTIONAL VIEW

How to fabricate HV cable TYPCY-1.5

3.In the order shown in the figure below, pass the gland nut, flat washers (3 pcs.) and gasket onto the HV cable.

4.As shown in the figure below, fold back the armor onto flat washer (2) and insert remaining armor through flat washer (3). Cut off the part of the armor that protrudes past the flat washers

(2) and (3).

Flat washer

(1) (2) (3)

HV cable

Gland nut

Cut off armor that

 

protrudes past washer.

 

Gasket

Passing flat washer, etc. onto HV cable

5.Pass the HV cable through its cable gland and then tighten gland nut.

6.Connect wiring to TB901, referring to the interconnection diagram.

7.Unfasten the gland nut for the power cable and remove gasket, flat washer (3 pcs.) and gland cap. (The gland cap may be discarded.)

2-6

Page 30
Image 30
Furuno FAR-2157-D Fabricating HV cable TYPCY-1.5 and power cable TYPCY-2.5, How to fabricate HV cable TYPCY-1.5