Chapter 5 TROUBLESHOOTING

5.1 Troubleshooting List

For qualified personnel only

The troubleshooting list below gives common symptoms of equipment malfunction and means to restore normal operation. If you cannot restore normal operation, please do not check inside any unit. Any repair is best left to a qualified radiotelephone technician. Improper handling or adjustment may cause more serious damage.

Troubleshooting list

TROUBLE

PROBABLE CAUSE

REMEDY

 

 

 

Power can not be turned on

The mains switchboard may be

Turn on the mains switch.

 

off.

 

 

DC overvoltage input.

Check supply voltage. It should

 

The battery may have

be less than 31.2V

 

Recharge battery and tighten

 

discharged, or poor contact at

terminal connections.

 

terminals.

 

 

Check fuse on the power cable

Replace the blown fuses.

 

or Power Supply Unit.

 

 

 

 

Frequency readout appears

The [DIMMER] key may be

Operate the [DIMMER] key.

but no lamps light

off.

 

 

 

 

Power is on but no sound

The [SPEAKER] key is off.

Press the [SPEAKER] key.

from loudspeaker

Volume may be too low.

Adjust the VOLUME control.

 

 

Squelch is on.

Press the [SQ] key if "SQ"

 

 

appears on the display.

 

Reduced RF Gain.

Turn the RF Gain control

 

 

clockwise.

 

 

 

Poor articulation

Wrong class of emission may

Select class of emission same as

 

be in use. (For example,

that of incoming signal.

 

receiving signal in J3E mode.

 

 

J3E should be used only on

 

 

2182 kHz.)

In Custom or ITU channel

 

 

 

Receiver detuned.

mode, press the [CLARIFY]

 

 

key then fine tune frequency by

 

 

the FREQ/CH control.

 

 

 

Output power is reduced to

Power is automatically reduced

Wait until the unit returns to

low ("LOW" indication

to protect against overheating

normal condition.

blinks)

due to continuous transmission.

 

 

 

 

-5.1-