Fusion L50B PRO operating instructions Error Messages, No Battery

Models: L50B PRO

1 16
Download 16 pages 4.91 Kb
Page 14
Image 14

INPUT BATTERY VOLTAGE ERROR

NO BATTERY

OUTPUT BATTERY REVERSE POLARITY

OUTPUT CIRCUIT PROBLEM

CHECK THE BATT. OPEN CIRCUIT

CHECK THE BATT. OVER VOLTAGE

CHECK THE BATT. LOW VOLTAGE

BALANCER VOLTAGE IS TOO HIGH

BALANCER VOLTAGE IS TOO LOW

DON’T CHARGE LiXX

WITH THIS MODE

ERROR MESSAGES

Input voltage is below 11.0V or exceeds 15V.

Battery is not connected to the charger’s output banana sockets.

Battery is connected to the output banana sockets in reverse.

The circuit of the charger has a problem.

Battery has become disconnected during an operation.

Wrong voltage is set while charging Lithium or Pb batteries.

Wrong voltage is set, or batteries are over discharged, while charging Lithium or Pb batteries.

Voltage per cell is too high during balancing. The pack may be faulty.

Battery cells are short-circuited during balancing. The pack may be faulty.

If the charger attempts to start charging with settings for NiCd/MH, or Pb batteries while there is a balancing cable connected to the balancing port of the charger. This helps prevent charging Lithium batteries in the wrong charge mode.

12

Page 14
Image 14
Fusion L50B PRO operating instructions Error Messages, No Battery