OPERATION

When the charger is connected to the power source the charger will show the battery mode that was last used.

If the battery TYPE button is briefly pressed, the present battery type (NiCd, NiMH, Lithium, or Pb ) will flash. While the existing battery type is flashing, every time the battery TYPE button is pressed, the following modes are shown in order:

NiCd CHARGE BATT TYPENiMH CHARGE BATT TYPE

C=3.0AC=3.0A

LiIo CHARGE

3.0A

BATT TYPE

 

C=3000mAh

10.8Vp

 

 

 

 

Pb CHARGE

BATT TYPE

 

C=3.0A 12V Pack

 

 

 

 

 

PROGRAMMING

NiCd Mode

BATT TYPE

CHARGE

INC

 

NiCd delta-peak-

 

C=3.0A

 

DEC

volt = 0mV/cell

 

ENTER

 

 

ENTER

INC

DEC

NiCd CHARGE

C=3

START

BATTERY CHECK

WAIT PLEASE....

CHG 0:00 00000 NC+3.00A 5.200V

INC

DEC

NiCd delta-peak- volt =

NiCd CHARGE C=3

NiCd delta-peak- volt =

Setting Charge Current

Adjust the desired charge current, which ranges from 0.1A to 6.0A with the INC & DEC buttons. Press the ENTER button to confirm the setting.

Setting Delta Peak Sensitivity

Set the Delta Peak Sensitivity from 5mV to 25mV per cell with the INC & DEC buttons and press the ENTER button to confirm the setting.

6

Page 8
Image 8
Fusion L50B PRO Operation, Programming, NiCd Mode, Setting Charge Current, Setting Delta Peak Sensitivity