7. Assembly instructions

7. Assembly instructions

7.1 Technical data

Heating output: Infrared grill: 3000 W

Dimensions (WxHxD): Outer: 288 x 125 x 510 mm

115/16 x 415/16 x 201/16

Inner: 265 x 125 x 490 mm

107/16 x 415/16 x 195/16

Ordering spare parts:

Gridiron

355443

Grill tongs

292464

Grill brush

098263

Lava stones

291050

7.2 Important notes on assembly

The installing technician is responsible for perfect functioning of the appliance at its installation location. He must explain the operating principle of the appliance to the user with reference to the operating instructions. He must draw the user's attention as to how to disconnect the appliance from the mains whenever necessary.

Any damage caused by failure to observe these instructions cannot be reimbursed.

Pay attention to the “Important notes" (Chapter 1).

Note: Several appliances can also be installed in individual recesses, as long as a minimum clearance of 40 mm (19/16”) is kept to between the appliances.

On installation, make sure that a minimum clearance of 35 mm (13/8”) from the wall trim or 50 mm (2”) from the wall is observed (measured from the edge of the appliance cutout). The building back wall and building side walls must consist of non com- bustible material or must be protected by no less than 1/4-inch-thick flame-retardant millboard covered with no less than No. 28 MSG sheet steel, 0.015-inch-thick stainless steel, 0.024-inch-thick aluminimum, or 0.020-inch-thick copper.

The distance from the bottom edge of the appliance tub to the next combustible item of furnishing must be at least 10 mm (13/32”).

Electrical connection

The appliance must only be connected by an authorised electrician, paying attention to all relevant codes.

Plug has to be conform with NEMA

CONFIGURATIONS FOR PLUGS AND

RECEPTACLES.

Plug must be rated not less than type 6-20 P (2-pole 3-wire grounding).

Only a qualified electrician should install this appliance.

The mains connecting cable must at least correspond to the type SJTO 3x16 AWG 105°C. You are advised to install a socket outlet (16 A fuse) grounded in accordance with regulations approximately 70 cm (271/2”) above the floor behind the appliance. This must still be accessible after installation.

The grill's power rating is 3.0 kW. Pay attention to the data on the rating plate. The appliance can be connected with a plug.

If damaged, the mains cable must be replaced by a special mains connecting cable. The mains connecting cable must only be connected by the manufacturer or the manufacturer's after-sales service.

The factory reserves the right to make technical modifications in the interest of progress!

VR 230-612

FD xxx

 

AC 208/220-240 V

60 Hz

2500/3000W

 

 

13A

 

 

 