7. Assembly instructions
7.1 Technical data
Heating output: Infrared grill: 3000 W
Dimensions (WxHxD): Outer: 288 x 125 x 510 mm
115/16 x 415/16 x 201/16”
Inner: 265 x 125 x 490 mm
107/16 x 415/16 x 195/16”
Ordering spare parts:
Gridiron | 355443 |
Grill tongs | 292464 |
Grill brush | 098263 |
Lava stones | 291050 |
7.2 Important notes on assembly
The installing technician is responsible for perfect functioning of the appliance at its installation location. He must explain the operating principle of the appliance to the user with reference to the operating instructions. He must draw the user's attention as to how to disconnect the appliance from the mains whenever necessary.
Any damage caused by failure to observe these instructions cannot be reimbursed.
Pay attention to the “Important notes" (Chapter 1).
Note: Several appliances can also be installed in individual recesses, as long as a minimum clearance of 40 mm (19/16”) is kept to between the appliances.
On installation, make sure that a minimum clearance of 35 mm (13/8”) from the wall trim or 50 mm (2”) from the wall is observed (measured from the edge of the appliance cutout). The building back wall and building side walls must consist of non com- bustible material or must be protected by no less than
The distance from the bottom edge of the appliance tub to the next combustible item of furnishing must be at least 10 mm (13/32”).
Electrical connection
The appliance must only be connected by an authorised electrician, paying attention to all relevant codes.
Plug has to be conform with NEMA
CONFIGURATIONS FOR PLUGS AND
RECEPTACLES.
Plug must be rated not less than type
Only a qualified electrician should install this appliance.
The mains connecting cable must at least correspond to the type SJTO 3x16 AWG 105°C. You are advised to install a socket outlet (16 A fuse) grounded in accordance with regulations approximately 70 cm (271/2”) above the floor behind the appliance. This must still be accessible after installation.
The grill's power rating is 3.0 kW. Pay attention to the data on the rating plate. The appliance can be connected with a plug.
If damaged, the mains cable must be replaced by a special mains connecting cable. The mains connecting cable must only be connected by the manufacturer or the manufacturer's
The factory reserves the right to make technical modifications in the interest of progress!
VR | FD xxx |
|
AC | 60 Hz | 2500/3000W |
|
| 13A |
|
|
|