6. Putting Your Water Timer Out of Operation
GB
Storage /
Overwintering:
Disposal:
(in accordance with RL2002/96/EC)
Disposing of flat batteries:
1.Turn
2.Store the Water Timer in a dry,
The product must not be added to normal household waste. It must be disposed of in line with local environmental regulations.
vImportant: Make sure that the unit is disposed of via your municipal recycling collection centre.
vPlease return flat batteries to a GARDENA dealer or dispose of them properly at your nearest recycling centre.
Only dispose of batteries when they are flat.
7. Maintenance
Clean filter:
7 |
B |
6 |
The filter B should be checked regularly and cleaned when necessary.
1.Unscrew sleeve nut 6 of the Water Timer by hand from the tap thread (do not use pliers).
2.If necessary unscrew the adaptor 7.
3.Remove filter B from sleeve nut 6 and clean.
4.Fit the Water Timer again (see 4. Putting Your Water Timer into Operation “Connecting Water Timer” ).
8. Trouble-Shooting
Fault | Possible cause | Remedy |
Not able to open manually | Battery capacity too low | v Insert a new alkaline battery. |
using “ON / OFF” | (Battery status LED flashes). |
|
|
|
|
| Tap turned off. | v Turn on tap. |
|
|
|
Watering is not | Program switched off: Turn | v Turn Run Time control |
carried out | Run Time control knob to | knob to the required |
| OFF or Reset. | watering duration. |
|
|
|
| Watering was started manually | v Turn Run Time control |
| and automatically ended after | knob to the required |
| 30 mins. Turn | watering duration. |
| knob to ON. |
|
|
|
|
| Battery capacity too low | v Insert a new alkaline |
| (Battery status LED flashes). | battery. |
|
|
|
| Battery incorrectly inserted. | v Observe polarity |
|
|
|
7